Vaillant 0010019230 Скачать руководство пользователя страница 5

Notes on the documentation 2

0020221303_02 uniSTOR HP Installation and maintenance instructions

5

2

Notes on the documentation

2.1

Observing other applicable documents

Always observe all the operating and installation instruc-
tions included with the system components.

2.2

Storing documents

Pass these instructions and all other applicable docu-
ments on to the end user.

2.3

Validity of the instructions

These instructions apply only to:

Product article number

VIH RW GB 150 BES

0010019230

VIH RW GB 200 BES

0010019231

VIH RW GB 250 BES

0010019232

VIH RW GB 300 BES

0010019233

2.4

Benchmark

Vaillant is a licensed member of the Benchmark Scheme.

Benchmark places responsibilities on both manufacturers
and installers. The purpose is to ensure that customers are
provided with the correct equipment for their needs, that it is
installed, commissioned and serviced in accordance with the
manufacturer’s instructions by a competent person approved
at the time by the Health and Safety Executive and that it
meets the requirements of the appropriate Building Regu-
lations. The Benchmark Checklist can be used to demon-
strate compliance with Building Regulations and should be
provided to the customer for future reference.

Installers are required to carry out installation, commission-
ing and servicing work in accordance with the Benchmark
Code of Practice which is available from the Heating and
Hotwater Industry Council who manage and promote the
Scheme.

Benchmark is managed and promoted by the Heating and
Hotwater Industry Council.

For more information visit www.centralheating.co.uk

3

Product description

3.1

Serial number

1

You can find the serial number on the data plate

(1)

, which is

located on the cylinder below the electronics box.

3.2

Information on the identification plate

The identification plate is attached to the product at the fact-
ory.

The identification plate keeps record of the country in which
the product is to be installed.

This product meets the requirements of standard EN
12897:2006.

3.3

CE marking

The CE marking shows that the products comply with the
basic requirements of the applicable directives as stated on
the declaration of conformity.

The declaration of conformity can be viewed at the manufac-
turer's site.

Содержание 0010019230

Страница 1: ...ation and maintenance instructions uniSTOR HP VIH RW GB BES GB IE Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 492191 18 0 Fax 492191 18 2810 info vaillant de www vaill...

Страница 2: ...6 Product dimensions standard diameter 8 5 Installation 8 5 1 Installing the product 8 5 2 Hydraulic connection 8 5 3 Electrical installation 11 6 Start up 14 6 1 Setting the immersion heater thermos...

Страница 3: ...ntenance instructions for the product and any other system com ponents installing and setting up the product in ac cordance with the product and system ap proval compliance with all inspection and mai...

Страница 4: ...correct tool 1 4 5 Risk of material damage caused by frost Do not install the product in rooms prone to frost 1 4 6 Risk of injury due to the heavy weight of the product Make sure that the product is...

Страница 5: ...ements of the appropriate Building Regu lations The Benchmark Checklist can be used to demon strate compliance with Building Regulations and should be provided to the customer for future reference Ins...

Страница 6: ...ation area Select a sensible installation site and take into consideration the routing of the pipework system Install the cylinder as close as possible to the heat generator in order to minimise heat...

Страница 7: ...d become damaged when unpacking the product Carefully unpack the product 3 Remove the product from its box 4 Remove the protective film from all of the product s components 4 4 Checking the scope of d...

Страница 8: ...transferred during welding may damage the cylinder and its components as well as the connection seals Protect the product and its components Do not weld the connection pieces if these have been screwe...

Страница 9: ...sible and with a maximum clearance of 600 mm from the connection of the temperature and pressure relief valve It must be installed in the same room as the cylinder but at a sufficient distance from el...

Страница 10: ...re that the discharge pipe from the tundish to the drain has a constant downward gradient of at least 1 200 The discharge pipe for the heat generator expansion relief valve can be connected to the hor...

Страница 11: ...ling through the product The product may be damaged by drilling work Do not drill through the product 70 60 50 40 70 60 50 40 1 3 2 4 1 3 2 4 1 2 3 4 1 Immersion heater 2 Immersion heater ther mostat...

Страница 12: ...ry circuit 4 Immersion heater tem perature control 5 3 4 Cable route Validity Except for VIH RW GB 150 BES Use the grommets that are included in the scope of delivery for the cylinder in the electroni...

Страница 13: ...nsor Condition With a multi functional module or control Connect the temperature sensor to the multi functional module or the control to do this see the instructions for the control or multi functiona...

Страница 14: ...ves for the purging 1 Check whether the drain valve is closed 2 Open the domestic hot water draw off valves 3 Open the water supply valve 4 Open the manual air separator at the top of the cylinder 5 L...

Страница 15: ...nd maintenance intervals Adhere to the minimum inspection and maintenance inter vals The inspection may require maintenance to be carried out earlier depending on the results Inspection and maintenanc...

Страница 16: ...stat to 55 C 4 Replace the thermostat Irregular domestic hot water output at the valve 1 Defective expansion vessel 2 Thermal control 1 Set the expansion vessel 2 Interrupt the power supply of the pro...

Страница 17: ...90 90 90 Load pressure in the expan sion vessel 0 3 MPa 3 0 bar 0 3 MPa 3 0 bar 0 3 MPa 3 0 bar 0 3 MPa 3 0 bar Maximum temperature of the heating circuit 95 95 95 95 Maximum domestic hot water temper...

Страница 18: ...30 V 50 Hz Immersion heater power 2 8 kW 2 8 kW 2 8 kW 2 8 kW Low loss header 230 240 V 50Hz 230 240 V 50Hz 230 240 V 50Hz 230 240 V 50Hz Thermostat 230 240 V 50Hz 230 240 V 50Hz 230 240 V 50Hz 230 24...

Страница 19: ...Appendix 0020221303_02 uniSTOR HP Installation and maintenance instructions 19 D Commissioning Checklist...

Страница 20: ...WUROV KDYH EHHQ WWHG LQ FRPSOLDQFH ZLWK 3DUW RI WKH XLOGLQJ 5HJXODWLRQV Yes Type of control system if applicable Y Plan S Plan Other Is the cylinder solar or other renewable compatible Yes No What is...

Страница 21: ...3 Date Engineer name Company name Telephone No Comments Signature SERVICE 05 Date Engineer name Company name Telephone No Comments Signature SERVICE 07 Date Engineer name Company name Telephone No Com...

Страница 22: ...5 Discharge pipe 9 Documents 5 Draining the product 15 E Electricity 3 F Filling and purging the primary circuit 14 Filling and purging the product 14 Frost 4 H Handing over to the end user 15 I Ident...

Страница 23: ......

Страница 24: ...byshire DE56 1JT Telephone 0330 100 3461 info vaillant co uk www vaillant co uk These instructions or parts thereof are protected by copyright and may be reproduced or distributed only with the manufa...

Отзывы: