8
Installation and maintenance instructions ecoTEC pro 0020209589_04
3
Technical data
Technical data
–
General
ecoTEC pro
30 H combi A
VUW 306/5
‑
3
Designated country (des-
ignation in accordance
with ISO 3166)
GB (Great
Britain), IE
(Ireland)
Approved unit categories
II
2H3P
Gas connection, boiler
side
15 mm
Flow/return heating con-
nections, boiler side
22 mm
Hot and cold water con-
nection, boiler side
G 3/4
″
Expansion relief valve
connection pipe (min.)
15 mm
Air/flue gas connection
60/100 mm
Condensate drain pipe-
work (min.)
19 mm
G20 natural gas flow
pressure
2.0 kPa
(20.0 mbar)
G31 propane gas flow
pressure
3.7 kPa
(37.0 mbar)
Gas flow rate at 15 °C
and 1013 mbar (based
on domestic hot water
generation, if applicable),
G20
3.2 m
³
/h
Gas flow rate at 15 °C
and 1013 mbar (based
on domestic hot water
generation, if applicable),
G31
2.4 kg/h
Min. flue gas mass flow
rate (G20)
2.96 g/s
Min. flue gas mass flow
rate (G31)
3.94 g/s
Max. flue gas mass rate
13.9 g/s
Min. flue gas temperature
40
℃
Max. flue gas temperat-
ure
70
℃
Approved gas-fired units
C13, C33,
C43, C53
30% efficiency
108 %
NOx class
6
Test symbol/registration
no.
CE
‑
0085CM0320
SAP 2009/2012 annual
efficiency (%)
89.3 %
Boiler dimension, width
440 mm
Boiler dimension, height
720 mm
Boiler dimension, depth
338 mm
Approx. net weight
39 kg
Technical data
–
G20 power/loading G20
ecoTEC pro
30 H combi A
VUW 306/5
‑
3
Nominal heat output
range P at 50/30 °C
6.9 to 25.7 kW
Nominal heat output
range P at 80/60 °C
8.0 to 24.7 kW
Maximum heat output
for domestic hot water
generation
30.0 kW
Maximum heat input for
domestic hot water gen-
eration
30.6 kW
Maximum heat input,
heating side
25.0 kW
Minimum heat input
8.5 kW
Heating adjustment range
6 to 24 kW
Technical data
–
Power/loading G31
ecoTEC pro
30 H combi A
VUW 306/5
‑
3
Nominal heat output
range P at 50/30 °C
9.0 to 25.7 kW
Nominal heat output
range P at 80/60 °C
6.2 to 24.4 kW
Maximum heat output
for domestic hot water
generation
30.0 kW
Maximum heat input for
domestic hot water gen-
eration
30.6 kW
Maximum heat input,
heating side
25.0 kW
Minimum heat input
8.7 kW
Technical data
–
Heating
ecoTEC pro
30 H combi A
VUW 306/5
‑
3
Maximum flow temperat-
ure
85
℃
Max. flow temperature
adjustment range (default
setting: 75 °C)
30 to 80
℃
Permissible total over-
pressure
0.3 MPa
(3.0 bar)
Minimum pressure for
full operation
0.08 MPa
(0.80 bar)
Expansion vessel capa-
city
10 l
Circulation water volume
(with reference to
Δ
T= 20 K)
1,049 l/h
Approx. condensate rate
(pH value 3.5 to 4.0) in
50/30 °C heating mode
2.5 l/h
Remaining feed head of
pump (at nominal circula-
tion water volume)
0.025 MPa
(0.250 bar)