3
Technical data
Technical data
–
General
VU 126/6-5
OVZ (H-GB)
VU 156/6-5
OVZ (H-GB)
VU 186/6-5
OVZ (H-GB)
VU 246/6-5
OVZ (H-GB)
VU 306/6-5
OVZ (H-GB)
VU 356/6-5
OVZ (H-GB)
Gas category
I
2H
I
2H
I
2H
I
2H
I
2H
I
2H
Diameter of the gas pipe
1/2 inch
1/2 inch
1/2 inch
1/2 inch
1/2 inch
1/2 inch
Diameter of the heating
connections
3/4 inch
3/4 inch
3/4 inch
3/4 inch
3/4 inch
3/4 inch
Expansion relief valve con-
nection pipe (min.)
15 mm
15 mm
15 mm
15 mm
15 mm
15 mm
Condensate discharge
pipe (min.)
21.5 mm
21.5 mm
21.5 mm
21.5 mm
21.5 mm
21.5 mm
G20 gas supply pressure
2.0 kPa
(20.0 mbar)
2.0 kPa
(20.0 mbar)
2.0 kPa
(20.0 mbar)
2.0 kPa
(20.0 mbar)
2.0 kPa
(20.0 mbar)
2.0 kPa
(20.0 mbar)
Gas flow at P max.
–
do-
mestic hot water (G20)
1.9 m
³
/h
1.9 m
³
/h
2.7 m
³
/h
3.2 m
³
/h
3.8 m
³
/h
3.8 m
³
/h
Gas flow at P max.
–
heat-
ing mode (G20)
1.3 m
³
/h
1.6 m
³
/h
1.9 m
³
/h
2.6 m
³
/h
3.2 m
³
/h
3.8 m
³
/h
Gas flow at P min. (G20)
0.480 m
³
/h
0.480 m
³
/h
0.533 m
³
/h
0.646 m
³
/h
0.762 m
³
/h
0.762 m
³
/h
CE number (PIN)
CE-
0063CP3646
CE-
0063CP3646
CE-
0063CP3646
CE-
0063CP3646
CE-
0063CP3646
CE-
0063CP3646
SAP 2009/2012 annual effi-
ciency (%)
89.8
89.8
89.7
89.7
89.7
–
Flue gas mass flow rate in
heating mode at P min.
2.08 g/s
2.08 g/s
2.31 g/s
2.80 g/s
3.30 g/s
3.3 g/s
Flue gas mass flow rate in
heating mode at P max.
5.5 g/s
6.9 g/s
8.3 g/s
11.1 g/s
13.8 g/s
16.1 g/s
Flue gas mass flow rate in
domestic hot water mode
at P max.
8.3 g/s
8.3 g/s
11.6 g/s
13.8 g/s
16.1 g/s
16.1 g/s
Flue gas temperature (80
°C/60 °C) at P max.
55
℃
55
℃
60
℃
77
℃
86
℃
86
℃
Flue gas temperature (80
°C/60 °C) at P min.
55
℃
55
℃
55
℃
55
℃
56
℃
56
℃
Flue gas temperature (50
°C/30 °C) at P max.
43
℃
48
℃
51
℃
60
℃
60
℃
60
℃
Flue gas temperature (50
°C/30 °C) at P min.
32
℃
32
℃
34
℃
35
℃
37
℃
37
℃
Flue gas temperature in
domestic hot water mode
71
℃
71
℃
69
℃
68
℃
75
℃
75
℃
Flue gas temperature when
overheating
105
℃
105
℃
105
℃
95
℃
104
℃
104
℃
Released system types
C13, C33,
C43, C53
C13, C33,
C43, C53
C13, C33,
C43, C53
C13, C33,
C43, C53
C13, C33,
C43, C53
C13, C33,
C43, C53
Nominal efficiency at
50/30 °C
104.0 %
104.0 %
104.0 %
104.0 %
104.0 %
104.0 %
Nominal efficiency at
40/30 °C
106.0 %
106.0 %
106.0 %
106.0 %
106.0 %
106.0 %
NOx class
6
6
6
6
6
6
Product dimensions, width
375 mm
375 mm
375 mm
375 mm
375 mm
375 mm
Product dimensions, depth
320 mm
320 mm
320 mm
320 mm
320 mm
320 mm
Product dimensions,
height
602 mm
602 mm
602 mm
602 mm
602 mm
602 mm
Net weight
23 kg
23 kg
23 kg
23 kg
23 kg
23 kg
Weight when filled with
water
27 kg
27 kg
27 kg
28 kg
28 kg
28 kg