CONNECTIONS
35
8.2 Motor connection
Motor connection of the DCS1 control system.
Data: Connection X2
Fig. 8-3 Connection X2 - motor connection
Type
Description
Connection X2
Harting HAN10B, PE,
bushing
Plug cycles
> 100
Power
Depending on the frequency con
-
verter used
Frequency
0 ... 120Hz
Pin
Function
Description
1
Motor phase U
Motor phase
2
Motor phase V
Motor phase
3
Motor phase W
Motor phase
4
Br+
Supply brake
5
Th+
Temperature monitoring
6
n.c
not connected
7
n.c
not connected
8
n.c
not connected
9
Br-
Supply brake
10
Th-
Temperature monitoring
PE
Earth conductor
Protective earth