Camera Settings
Use the DIP switches to set other camera behaviors.
Note
When the camera is right side up, switches are in their default positions when they are up.
IR Frequency Selection:
The IR Remote Commander can control up to three cameras in the same room
independently, if they are configured with different IR frequencies. Use
switches 1 and 2
to select the
frequency to identify the camera as camera 1, 2, or 3; then use the Camera Select buttons at the top of the
remote to select the camera you want to control.
IR:
Leave
switch 3
in the default UP position if the IR remote will be used.
Inverted operation:
If mounting the camera upside-down, set
switch 4
to the DOWN position: IMAGE
FLIP ON.
Baud Rate:
Set the baud rate for RS-232 communication using
switch 5
. Most applications use 9600 bps
(switch 6 UP), which is recommended when using long cable runs. Use the 38,400 bps setting (switch 6
DOWN) for short control lines only.
Switch 6
is not currently used.
Pro Tip
Double-check switch settings before you mount the camera.
6