Command List 
(Continued) 

One Push Trigger 

8x 01 04 18 01 FF 

One Push AF Trigger 

Infinity 

8x 01 04 18 02 FF 

Forced Infinity 

Near Limit 

8x 01 04 28 0p 0q 0r 0s FF 

pqrs: Focus Near Limit Position 

Normal 

8x 01 04 58 02 FF 

AF Sensitivity Norm/Low 

AF Sensitivity 

Low 

8x 01 04 58 03 FF 

  

CAM_ZoomFocus Direct 

8x 01 04 47 0p 0q 0r 0s 0t 0u 0v 

0w FF 

    pqrs:  Zoom Position 
    tuvw: Focus Position 

Auto 

8x 01 04 35 00 FF 

Normal Auto 

Indoor 

8x 01 04 35 01 FF 

Indoor Mode 

Outdoor 

8x 01 04 35 02 FF 

Outdoor Mode 

One Push WB 

8x 01 04 35 03 FF 

One Push WB Mode 

ATW 

8x 01 04 35 04 FF 

Auto Tracing White Mode 

Manual 

8x 01 04 35 05 FF 

Manual Control Mode 

CAM_WB 

One Push Trigger 

8x 01 04 10 05 FF 

One Push WB trigger 

Reset 

8x 01 04 03 00 FF 

R Gain Manual setting 

Up 

8x 01 04 03 02 FF 

  

Down 

8x 01 04 03 03 FF 

  

CAM_RGain 

Direct 

8x 01 04 43 0p 0q 0r 0s FF 

pqrs: R Gain 

Reset 

8x 01 04 04 00 FF 

B Gain Manual setting 

Up 

8x 01 04 04 02 FF 

  

Down 

8x 01 04 04 03 FF 

  

CAM_BGain 

Direct 

8x 01 04 44 0p 0q 0r 0s FF 

pqrs: B Gain 

Full Auto 

8x 01 04 39 00 FF 

Automatic exposure mode 

Manual 

8x 01 04 39 03 FF 

Manual control mode 

Shutter Priority 

8x 01 04 39 0A FF 

   Shutter priority auto exposure   mode 

Iris Priority 

8x 01 04 39 0B FF 

Iris priority auto exposure mode 

CAM_AE 

Bright 

8x 01 04 39 0D FF 

Bright mode (Manual

 

Auto 

8x 01 04 5A 02 FF 

AutoSlowShutter ON/OFF 

CAM_SlowShutter 

Manual 

8x 01 04 5A 03 FF 

  

Reset 

8x 01 04 0A 00 FF 

Shutter setting 

1/4sec

1/10000sec

 

Up 

8x 01 04 0A 02 FF 

  

Down 

8x 01 04 0A 03 FF 

  

CAM_Shutter 

Direct 

8x 01 04 4A 00 00 0p 0q FF 

pq: Shutter Position            

Reset 

8x 01 04 0B 00 FF 

Iris setting 

Up 

8x 01 04 0B 02 FF 

  

Down 

8x 01 04 0B 03 FF 

  

CAM_Iris 

Direct 

8x 01 04 4B 00 00 0p 0q FF 

pq: Iris Position 

Reset 

8x 01 04 0C 00 FF 

Gain setting    

CAM_Gain 

Up 

8x 01 04 0C 02 FF 

  

Содержание CeilingVIEW 70 PTZ HideAway

Страница 1: ...ers and reveals the camera Contact closure or voltage sensing can be used to activate the lift system remotely or the camera IR remote control can be used to activate the lift with the ON OFF button The VISCA control interface is included to allow the camera to work with any other VISCA compatible control device The PowerRite power supply regulates the right amount of power needed for the camera o...

Страница 2: ...ly One 1 12 4 57m S Video cable One 1 12 4 57m Composite Video cable Two 2 Adjustable ceiling tile support rails One 1 RJ 45 to DB9 EZCamera serial control converter Mounting Hardware Installation and User Guide 341 075 Rev C UNPACKING Use only the power supply provided with the CeilingVIEW 70 PTZ HideAway camera system Use of any unauthorized power supply will void any and all warranties IMPORTAN...

Страница 3: ...g ease remove the marked ceiling tile and place on a suitable and safe work surface Note If camera is to be controlled as part of a multi camera system please refer to the section CHANGING CAMERA DEFAULT SETTINGS located on Page 7 of this manual To mount the CeilingVIEW 70 PTZ HideAway 1 Attach a string or plumb bob to the ceiling tile with a thumbtack 2 Position the string directly over ample tab...

Страница 4: ...ite Video outputs are active 8 If needed Cat 5 plenum rated cable s may be purchased from Vaddio to connect your camera for video power control and control daisy chaining between multiple cameras see Figure 6 CAMERA THUMB SCREW 24 BRACKET WASHERS Figure 4 Side View and Close up of Camera module and support rail Cabling the Camera S Video Output to Display Device Composite Video Output to Display P...

Страница 5: ...in the suspended ceiling at this time 11 Locate the white trim ring assembly and plug the IR cable into the IR board connector on the trim ring lip see Figure 8 Take care not to pull any more than about 2 inches of cable from the camera enclosure The connectors will fit together only one way with a positive click Note DO NOT hang the trim ring from the camera by the IR cable Carefully move trim ri...

Страница 6: ...rol system i e Crestron or AMX plug the Cat 5 cable from the RS 232 IN jack on the camera to your control system using the Cat 5 to DB9 serial adapter supplied by Vaddio If you are controlling more than one camera plug the Cat 5 cable from the RS 232 OUT jack on the first camera to the RS 232 IN jack on the second camera Repeat procedure if third camera is to be used If control of motor only is de...

Страница 7: ...ding the IR cable back through hole Looking between the rear of the EVI D70 camera body and the interconnect circuit board locate the 2 switches it may be necessary to slightly tilt the camera assembly to get the best view of the switches The default setting for the image flip function is ON Move this switch to the left to disable The default setting for IR select is 1 If this to be camera number ...

Страница 8: ... FF Address setting IF_Clear Broadcast 88 01 00 01 FF I F Clear CommandCancel 8x 2p FF p Socket No 1or2 On 8x 01 04 00 02 FF Power ON Lowers Camera Lift Mechanism and Turns camera ON CAM_Power Off Standby 8x 01 04 00 03 FF Power OFF Retracts Camera Lift Mechanism and Turns camera OFF Stop 8x 01 04 07 00 FF Tele Standard 8x 01 04 07 02 FF No Wide Standard 8x 01 04 07 03 FF Tele Variable 8x 01 04 07...

Страница 9: ...ng Up 8x 01 04 03 02 FF Down 8x 01 04 03 03 FF CAM_RGain Direct 8x 01 04 43 0p 0q 0r 0s FF pqrs R Gain Reset 8x 01 04 04 00 FF B Gain Manual setting Up 8x 01 04 04 02 FF Down 8x 01 04 04 03 FF CAM_BGain Direct 8x 01 04 44 0p 0q 0r 0s FF pqrs B Gain Full Auto 8x 01 04 39 00 FF Automatic exposure mode Manual 8x 01 04 39 03 FF Manual control mode Shutter Priority 8x 01 04 39 0A FF Shutter priority au...

Страница 10: ...3 FF CAM_SpotAE Position 8x 01 04 29 0p 0q 0r 0s FF pq X 0 to F rs Y 0 to F Reset 8x 01 04 02 00 FF Aperture Control Up 8x 01 04 02 02 FF Down 8x 01 04 02 03 FF CAM_Aperture CAM_Aperture Direct 8x 01 04 42 0p 0q 0r 0s FF pqrs Aperture Gain On 8x 01 04 61 02 FF Mirror Image ON OFF CAM_LR_Reverse Off 8x 01 04 61 03 FF On 8x 01 04 62 02 FF Freeze Picture ON OFF CAM_Freeze Off 8x 01 04 62 03 FF Off 8x...

Страница 11: ... the original data 02 Detect the AE level Not update the original data SetMode 8x 01 04 6C pp FF 03 Detect the AE level Update the original data SetDayNightLevel 8x 01 04 6D 0p 0p 0p 0q 0q 0q FF Set the AE level of judgment of Day ppp and Night qqq y0 07 04 6B 01 FF Detect level Low to High CAM_Alarm Alarm Reply y0 07 04 6B 00 FF Detect level High to Low Up 8x 01 06 01 VV WW 03 01 FF Down 8x 01 06...

Страница 12: ... system is the correct camera being addressed Camera will not respond to control system RS 232 control commands Is the camera power on Specification CeilingVIEW 70 PTZ HideAway Part Number 999 2404 000 999 2404 001 Signal system NTSC PAL Image sensor 1 4 type EXview HAD CCD Effective Pixels 768 x 494 H x V 752 x 582 H x V Horizontal Resolution 470 TV lines 460 TV lines Lens 18X Optical Zoom f 4 1 ...

Страница 13: ...e reason for repairs or returns as well as the date of purchase Include your assigned RMA number in all correspondence with Vaddio Write your assigned RMA number on the outside of the box when returning the product Voided warranty The warranty does not apply if the original serial number has been removed or if the product has been disassembled or damaged through misuse accident modifications or un...

Страница 14: ...4 www vaddio com Ⓒ2006 Vaddio All Rights Reserved Reproduction in whole or in part without written permission is prohibited Specifications and pricing are subject to change without notice CeilingVIEW WallVIEW ControlVIEW EZCamera and PowerRite are registered trademarks of Vaddio Inc All other trademarks are property of their respective owners Form Number 341 075 Rev D ...

Отзывы: