If the measures listed in section ”Troubleshooting” do not work: Return the equip-

ment to the factory for inspection and repair.

Interference with the equipment (except replacement of the battery) voids all war-

ranties.

Safety and health of our staff, laws and regulations regarding the handling of dan-

gerous goods, occupational health and safety regulations and regulations regarding 

safe disposal of waste require that for all pumps and other products the 

“Health and 

safety clearance form“

 must be sent to our office duly completed and signed before 

any equipment is dispatched to our premises.

Fax or post a completed copy of the health and safety clearance form to us in ad

-

vance. The declaration must arrive before the equipment. Enclose a second com-

pleted copy with the product. If the equipment is contaminated you must notify the 

carrier.

No repair / DAkkS calibration is possible unless the correctly completed form 

is returned. Inevitably, there will be a delay in processing the equipment if in-

formation is missing or if this procedure is not obeyed.

 

Eventually, acceptance 

of the returned equipment will be refused.

If the product has come in contact with chemicals, radioactive substances or other 

substances dangerous to health or environment, the product must be decontami-

nated 

prior to sending it back to the factory.

To expedite repair and to reduce costs, please enclose a detailed description of 

the problem and the product’s operation conditions with every product returned for 

repair.

We submit 

quotations

 only on request and always at the customer’s expense. If 

an order is given, the costs incurred are offset from the costs for repair or from the 

purchase price, if the customer prefers to buy a new product instead of repairing the 

defective one.

  If you do not wish a repair on the basis of our quotation, the equipment 

might be returned to you disassembled and at your charge!

We replace parts due to optical aspects upon your request (at your expense).

Before returning

 the equipment ensure that (if applicable):

  Equipment has been cleaned and/or decontaminated.

  All ports have been sealed.

  Equipment has been properly packed, if necessary, please order an original pack-

aging (costs will be charged), marked as appropriate and the carrier has been 

notified.

  Ensure that the completed health and safety clearance form is enclosed.

We hope for your understanding for these measures, which are beyond our control.

Scrapping and waste disposal:

Dispose of the equipment and any components removed from it safely in accord-

ance with all local and national safety and environmental requirements. Particular 

care must be taken with components which have been contaminated with dangerous 

substances from the process. Do not incinerate fluoroelastomer seals and O-rings.

  You may authorize us to dispose of the equipment 

at

 

your expense.

Notes on return to the factory

Repair - return  - DAkkS calibration

NOTICE

NOTICE

Содержание DVR 2

Страница 1: ...ompletely and unchanged It is strictly the users responsibility to check carefully the validity of this document with respect to his product manual no 999001 04 04 2012 DVR 2 Analog Digital Rough Vacu...

Страница 2: ...our company is tested in tensively including an endurance run Therefore faults even those which occur rarely are identified and can be eliminated immediately The achievement of the specifications afte...

Страница 3: ...t of the vacuum gauge DVR 2 11 Adjustment at atmospheric pressure 11 Adjustment under vacuum 11 Adjustment to a reference pressure 12 Calibration in the factory 12 Replacing the battery 13 Notes on re...

Страница 4: ...sing check maximum temperature Ensure that the maximum permitted gas temperature at the pressure transducer see Technical data is not exceeded Use the equipment and all system parts for the intended u...

Страница 5: ...mixtures Ensure that the materials of the equipment s wetted parts are compatible with the substances in the vacuum system see section Technical data Safety during operation Adopt suitable measures to...

Страница 6: ...nterior components of the device can only be repaired at the factory Returned products will not be repaired or calibrated until the completed health and safety clearance form has been received In orde...

Страница 7: ...reful adjustment and at constant temperature 1 mbar 0 75 Torr 1 digit Temperature coefficient 0 07 mbar K 0 05 Torr K Maximum permissible temperature of gaseous media at pressure transducer continuous...

Страница 8: ...key Switch the vacuum gauge off Press MODE key and keep it pressed while switching the DVR 2 on ON OFF key The pressure unit as of the last operation Torr mbar or hPa is displayed Press ON OFF key to...

Страница 9: ...easuring cycle frequent measurement in case of great pressure change S1 1 measurement in 3s S2 1 measurement in 1s S3 3 measurements in 1s The flashing of the arrow only S1 S2 or S3 symbol izes the fr...

Страница 10: ...cause Remedy No display or display disappears Automatic sleep mode Switch on increase opera ting time if necessary Battery flat Replace battery Other cause Contact local distributor Incorrect pressure...

Страница 11: ...tion Determine the exact actual atmospheric pressure e g by using an accurate barometer or get accurate reading from the weather service e g at the next airport etc take into account the differ ence i...

Страница 12: ...e calibra tion of inspection measuring and test equipment at specified intervals To document that the vacuum gauges calibrated are traceable to national standards of the PTB Physikalisch Technische Bu...

Страница 13: ...Technical data The battery must not be charged or connected to an external voltage Remove the battery Insert the new battery into the battery compartment cor rectly matching the positive and negative...

Страница 14: ...nvironment the product must be decontami nated prior to sending it back to the factory To expedite repair and to reduce costs please enclose a detailed description of the problem and the product s ope...

Страница 15: ...n in contact with the device are listed in section 5 and that the information is complete and that we have not withheld any information We declare that all measures where applicable have been taken li...

Страница 16: ...ummer Order number Num ro d article 682902 Seriennummer Serial number Num ro de s rie Siehe Typenschild See rating plate Voir plaque signal tique Angewandte harmonisierte Normen Harmonized standards a...

Страница 17: ...lts obtained under test conditions for specific applications depend on a number of factors beyond our control It is therefore strictly the users responsibility to very carefully check the validity of...

Отзывы: