vacuubrand DCP 3000 Скачать руководство пользователя страница 1

page 1 of 36

Documents are only to be used and distributed completely and unchanged. It is strictly the users´ responsibility to check carefully 

the validity of this document with respect to his product. Manual-no.: 999162 // 19/01/2011

Vacuum gauge

Technology for Vacuum Systems

Instructions for use

DCP 3000

Содержание DCP 3000

Страница 1: ...ributed completely and unchanged It is strictly the users responsibility to check carefully the validity of this document with respect to his product Manual no 999162 19 01 2011 Vacuum gauge Technolog...

Страница 2: ...application usage and personal safety through our products Please read these instructions for use before the initial operation of your device VACUUBRAND vacuum gauges are the result of many years of e...

Страница 3: ...the validity of this document with respect to his product Manual no 999162 19 01 2011 Portugu ycc Polski Nederl Suomi DCP 3000 V2 0 Deutsch English Fran ais Italiano Espa ol T rk e Reset Language sel...

Страница 4: ...ucers 19 Manual switching between pressure transducers 19 Automatic switching between pressure transducers VSK 3000 and VSP 3000 19 Measuring differential pressure 20 Reconfiguring the pressure transd...

Страница 5: ...onnected combined and operated according to their design and as indicated in the instructions for use Comply with notes on correct vacuum and electrical connections see section Use and operation The d...

Страница 6: ...dopt suitable safety measures Ambient conditions To the best of our knowledge the equipment is in compliance with the requirements of the applicable EC directives and harmonized standards with regard...

Страница 7: ...e that in case of failure the device and the vacuum system always will turn into a safe status Maintenance and repair Before starting maintenance unplug the power supply wall plug Wait two minutes aft...

Страница 8: ...eration no condensation 30 to 85 Maximum permissible range of supply voltage 24 V 6V Maximum permissible current of connected valves connected components 4A with sufficiently powerful power supply Max...

Страница 9: ...nt connection continuous operation 40 C for short periods 5 minutes up to 80 C Temperature coefficient 0 07 mbar K 0 05 Torr K not specified Ambient temperature range operation 10 C to 40 C Ambient te...

Страница 10: ...ponents Wetted materials VSK 3000 Sensor aluminium oxide ceramics Sensor housing measurement chamber PPS glass fibre Seal at sensor chemically resistant fluoroelastomer Hose nozzle PP Clamping ring PA...

Страница 11: ...the device is displayed Select the desired language e g English by turning the selection knob and press to con firm Then select the pressure unit mbar Torr or hPa in the same way It is possible to acc...

Страница 12: ...ction knob Press to reach the set up menu of the function Turn to reach the parameter set up Press to reach the set value Turn to change the set value Press to confirm and to reach further parameters...

Страница 13: ...ge and is related to the molecular mass The thermal conductivity of gases and vapours varies with their molecular mass Therefore the pressure measurement is dependent on the gas type The pressure tran...

Страница 14: ...CUU BUS line or the power supply of the controller or vacuum gauge The interior of the pressure transducer is highly sensitive Do not insert fingers or tools into the measuring chamber VACUU BUS Reado...

Страница 15: ...er than in the system Therefore choose carefully the position where to connect the gauge head Condensate and deposits at the gauge head falsify the measurement result If residues occur or when working...

Страница 16: ...c Back Display Brightness 100 Contrast 40 Sound Off Unit mbar Language English Back Sensors VSK 1 1001 mbar VSP 1 1 0E 3 mbar VSK 2 780 mbar VSP 2 7 8E 2 mbar Back Switching between pressure transduce...

Страница 17: ...al pressure range mbar is displayed RS 232 Configuration of the interface setting of parameters and commands see section Interface parameters Baud rate is selectable on 19200 9600 4800 or 2400 parity...

Страница 18: ...It is strictly the users responsibility to check carefully the validity of this document with respect to his product Manual no 999162 19 01 2011 Configuration Adjustment 1000 mbar RS 232 Sensors Disp...

Страница 19: ...tween pressure transducers 1st possibility Select the menu item Sensors in the menu Configuration Connected pressure transducers are displayed in the order of their VACUU BUS address VSK 1 VSP 1 VSK 2...

Страница 20: ...VSK 3000 Configuration of the MPT 100 See instructions for use of MPT 100 Reconfiguring the VACUU BUS address of a pressure transducer 1 Switch the vacuum gauge DCP 3000 off 2 Preferably connect only...

Страница 21: ...oint Off 1 is set to 70 mbar the valve closes at a pressure less than or exactly 70 mbar the valve opens if the pressure exceeds 70 mbar A setpoint can be used e g to open a valve assembled between a...

Страница 22: ...mmunication current supply for Bluetooth adapter on pin 9 see Connector assignment Settings via interface are stored Setting the interface Set the interface parameters directly at the DCP 3000 The fac...

Страница 23: ...out of the stored readings is possible via RS 232 interface with the selected transfer para meters see Configuration of the interface The data output format is ASCII First the time is recorded then t...

Страница 24: ...IN_PV_X IN_PV_D IN_CFG Read commands 0 last command to serial interface correct 1 last command to serial interface incorrect 0 no external fault 1 external fault 0 no fault at the pressure transducer...

Страница 25: ...of this document with respect to his product Manual no 999162 19 01 2011 Description setpoint On 1 setpoint On 2 setpoint On 3 setpoint On 4 setpoint Off 1 setpoint Off 2 setpoint Off 3 setpoint Off 4...

Страница 26: ...r recording 0 venting valve closed 1 venting valve open 2 venting until atmospheric pressure 1 8 external sensors if connected switch off device switch on device The single abbreviations of a command...

Страница 27: ...neces sary The pressure reading is too high in the low pres sure range Pressure transducer contami nated Clean pressure transducer and readjust Pressure transducer not cor rectly adjusted Readjust pre...

Страница 28: ...Module VACUU BUS fault indicator 636228 Analog I O Module VACUU BUS analog voltage output of vacuum reading 636229 PC Software VACUU CONTROL 692920 VACUUBRAND valve with diode plug Conversion kit val...

Страница 29: ...se the gauge head chamber several times with alcohol in order to remove all solvent residues Allow the pressure transducer to dry Readjust the pressure transducer if necessary Cleaning the pressure tr...

Страница 30: ...ent the device has to be adjusted both at atmospheric pressure as well as under vacuum For readjustment the reference pressures have to be known pre cisely In the range between 20 and 700 mbar no adju...

Страница 31: ...is displayed Adjustment at atmospheric pressure An adjustment at atmospheric pressure is only possible in the upper pressure range Ventilate the pressure transducer VSP 3000 and or the vac uum system...

Страница 32: ...nditions with every product returned for repair We submit quotations only on request and always at the customer s expense If an order is given the costs incurred are offset from the costs for repair o...

Страница 33: ...he returned product that neither toxic corrosive biologically active explosive radio active nor contamination dangerous in any way has occurred the product is free of dangerous substances the oil or r...

Страница 34: ...00 DCP 3000 VSP 3000 Artikelnummer Order number Num ro d article 683170 683190 Seriennummer Serial number Num ro de s rie Siehe Typenschild See rating plate Voir plaque signal tique Angewandte harmoni...

Страница 35: ...ly and unchanged It is strictly the users responsibility to check carefully the validity of this document with respect to his product Manual no 999162 19 01 2011 This certificate is only valid for dev...

Страница 36: ...obtained under test conditions for specific applications depend on a number of factors beyond our control It is therefore strictly the users responsibility to very carefully check the validity of app...