Description of parameters
vacon • 53
24-hour s358 (0)40 837 1150 • Email: [email protected]
4.1
Keypad control parameters
Unlike the parameters listed above, these parameters are located in the M3 menu of the control keypad.
The reference parameters do not have an ID number.
114
Stop
button
activated
(3.4)
If you wish to make the Stop button a "hotspot" which always stops the drive regardless of the
selected control place, give this parameter the value 1.
See also parameter ID125.
125
Control
place
(3.1)
The active control place can be changed with this parameter. For more information, see the
product's user's manual.
Pushing the
Start button
for 3 seconds selects the control keypad as the active control place
and copies the Run status information (Run/Stop, direction and reference).
123
Keypad
direction
(3.3)
0
Forward: The rotation of the motor is forward, when the keypad is the active control
place.
1
Reverse: The rotation of the motor is reversed, when the keypad is the active control
place.
For more information, see the product's user's manual.
R3.2
Keypad
Reference
(3.2)
The frequency reference can be adjusted from the keypad with this parameter.
The output frequency can be copied as the keypad reference by pushing the
Stop button
for 3
seconds when you are on any of the pages of menu
M3.
For more information, see the
product's user's manual.
R3.4
PID
reference
1
(3.4)
With this parameter, you can set the desired temperature for the coolant circulating in the
system.
R3.5
PID
reference
2
(3.5)
With this parameter, you can set another, optional temperature for the coolant circulating in
the system. The value is activated by setting the value 10 for parameter