![Vacon FI4 Скачать руководство пользователя страница 56](http://html1.mh-extra.com/html/vacon/fi4/fi4_user-manual_847727056.webp)
54 • vacon
control keypad
Tel. +358 (0)201 2121 • Fax: +358 (0)201 2121 205
7
7.3.3.4
Stop button activated
By default, pushing the STOP button will always stop the motor regardless of the selected control
place. You can disable this function by giving parameter 3.4 the value 0. If the value of this parameter
is 0, the STOP button will stop the motor only when the keypad has been selected as the active
control place.
Note: For additional information on controlling the motor with the keypad, see Chapters 7.2.1, 7.3.3
and 8.2.
NOTE!
There are some special functions that can be performed in menu M3:
Select the keypad as the active control place by pressing START for 3 seconds when
the motor is running. The keypad will become the active control place and the current
frequency reference and direction will be copied to the keypad.
Select the keypad as the active control place by pressing STOP for 3 seconds when
the motor is stopped. The keypad will become the active control place and the current
frequency reference and direction will be copied to the keypad.
Copy the frequency reference set elsewhere (I/O, fieldbus) to the panel by pressing
enter
for 3 seconds.
Note that if you are in any other than menu
M3 these functions will not work.
If you are in some other than menu
M3 and try to start the motor by pressing the START button
when the keypad is not selected as the active control place, you will get an error message:
Keypad
Control NOT ACTIVE.