5.1 Monitoring values
The monitoring values are the actual values of parameters and signals as well as statuses
and measurements.
Note for DriveSynch Systems:
In a DriveSynch system, only Master drive monitoring signals are reliable.
Only directly measured values are reliable in follower units. Even the Output Frequency of
DriveSynch follower is not directly observed and thus may not show actual output frequency
that is controlled by DriveSynch Master Drive.
Code
Parameter
Unit
Form.
ID
Description
V1.1
Output frequency
Hz
#,##
1
Output frequency to motor
V1.2
Frequency reference
Hz
#,##
25
Frequency reference to motor control
V1.3
Motor speed
rpm
#
2
Motor speed in rpm
V1.4
Motor current
A
Varies
3
1 s linear filtering
V1.5
Motor torque
%
#,#
4
In % of Motor nominal torque
V1.6
Motor Power
%
#,#
5
V1.7
Motor voltage
V
#,#
6
Calculated motor voltage
V1.8
DC link voltage
V
#
7
Measured DC voltage, filtered.
V1.9
Unit temperature
C
#
8
Heatsink temperature
V1.10
Motor temperature
%
#
9
Calculated motor temperature, trip 105%
V1.11
Analogue input 1
%
#,##
13
AI1, unfiltered.
V1.12
Analogue input 2
%
#,##
14
AI2, unfiltered.
V1.13
Analogue input 3
%
#,##
27
AI3, unfiltered.
V1.14
Analogue input 4
%
#,##
28
AI4, unfiltered.
V1.15
Analogue Out 1
%
#,##
26
AO1
V1.16
Analogue Out 2
%
#,##
31
AO2
V1.17
Analogue Out 3
%
#,##
32
AO3
V1.18
Analogue Out 4
%
#,##
1526
V1.19
DIN1, DIN2, DIN3
#
15
Digital input statuses
V1.20
DIN4, DIN5, DIN6
#
16
Digital input statuses
V1.21
Power Reference
%
#,#
1700
Used power reference
V1.22
PT-100 Temperature
Cº
#,#
42
Highest temperature of OPTB8 board. 4 s
filtering.
G1.23
Multimonitoring items
Displays three selectable monitoring
values
Table 5-1. Monitoring values