2.
APFIFF09 VERSIONS COMPATIBILITY ISSUES
Latest released and previous versions from this link
V120
-
Temperature measurement board 2 has own response parameter.
V122
-
Speed error monitoring status bits are moved from Fault Word 2 to Fault Word 10 B0
and from Warning Word 1 to Warning Word 10 B0
V128
-
In earlier version, when operating in Ramp Follower mode, the follower brake control
closed the brake after the master drive was in stop state. Now brake is closed in this
mode at the same time as the master drive is closing the brake.
V215
-
Stop Torque Release Time ID changed from 1848 to 1858
Note 1:
When updating application, it is not recommended to use VACON
®
NCDrive
parameter download function. Instead, upload the parameters from the unit and make
comparison to the old parameter file. Application is constantly developed, this includes
changing parameter default values. If parameters are directly downloaded to drive, the
improved default values will be lost.