6 • vacon
Lift Application – Parameter lists
Tel. +358 (0)201 2121 • Fax +358 (0)201 212 205
3.2
Motor Parameters (Control keypad: Menu P2
Æ
P2.1)
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Note
P2.1.1
180 690 V
NXL2:230V
NXL5:400V
110
P2.1.2
0,00 320,00 Hz 50,00
111
Check the rating plate of
the motor
P2.1.3
0 20
000
Rpm
rpm
112
The default applies for a 4-
pole motor and a nominal
size frequency converter.
P2.1.4
0,3 x I
L
1,5 x I
L
A
I
L
113
Check the rating plate of
the motor
P2.1.5
0,30
1,00 0,85
120
Check the rating plate of
the motor
P2.1.6
0,1 x I
L
1,5 x I
L
A
I
L
107
NOTE: Formulas apply
approx. up to MF3. For
greater sizes consult the
factory.
Table 1-2. Motor parameters P2.1
3.3
Speed control (Control keypad: Menu P2
Æ
P2.2)
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Note
P2.2.1
0,20 5,00 m/s 1,00
1600
Nominal speed for lift
P2.2.2
0 4 0
1601
0=Activity Reference
1=Activity Reference with
direction
2=Binary reference
3=Fieldbus
4=Keypad
P2.2.3.x
Speed Reference [m/s]
P2.2.3.1
0,00 par2.2.1
m/s 0,10
1602
P2.2.3.2
0,00 par2.2.1
m/s 1,00 1603
P2.2.3.3
par2.2.1
m/s 0,25 1604
P2.2.3.4
1,5 x
par2.2.1
m/s 0,50
1605
P2.2.3.5
0,00 par2.2.1 m/s 0,10
1606
P2.2.3.6
0,00 par2.2.1 m/s 1,00
1607
P2.2.3.7
0,00 par2.2.1 m/s 0,25
1608
P2.2.3.8
0,00 par2.2.1 m/s 0,50
1609
P2.2.3.9
1,5 x
par2.2.1
m/s 0,10
1610