Vacon 100X Solar Pump Application
vacon • 2
Service support: find your nearest Vacon service center at www.vacon.com
1
1.
V
ACON
100X S
OLAR
P
UMP
A
PPLICATION
The Vacon AC drive contains a preloaded Vacon 100X Solar Pump application for instant use.
1.1
Specific functions of Vacon Solar pump application
The Vacon 100X Solar Pump application allows flexible use of VACON
®
100X frequency con-
verters. This dedicated application SW was developed to drive a Solar Pump with an optimized
MPPT (Maximum Power Point Tracking) for 100X supplied by Solar Panels.
The MPPT is based on 4 parallel algorithms:
•
Feed-Forward Controller (to follow the radiation variations)
•
Correction Controller (to compensate the temperature variations)
•
Oscillation Damping Regulator (to prevent the panel entering in the “current source”
branch of the characteristic)
•
Local Maxima logic (to prevent the regulator from being trapped in a local maximum
lower than absolute maximum)
Features
•
The MPP Tracker controls DC voltage reference in order to find the maximum power.
•
Extensive wizards
for start-up, PID-control used to facilitate commissioning
•
‘Funct’ button
for easy change between Local (keypad) and Remote control place. The
remote control place is selectable by parameter (I/O or Fieldbus)
•
8 preset frequencies
•
Motor pontentiometer
functions
•
2 programmable
ramp times
, 2
supervisions
and 3 ranges of
prohibited frequencies
•
Control page
for easy operation and monitoring of the most essential values.
•
Fieldbus
data mapping
•
Automatic reset
•
Different
pre-heat modes
used to avoid condensation problems
•
Maximum output frequency 320Hz
•
Real-time clock and timer functions
available (optional battery required). Possible to
program 3 time channels to achieve different functions on the drive (e.g. Start/Stop and
Preset frequencies)
•
External PID-controller
available. Can be used to control e.g. a valve using the AC
drive's I/O
•
Sleep mode function
which automatically enables and disables drive running with user
defined levels to save energy.
•
2-zone PID-controller
(2 different feedback signals; minimum and maximum control)
•
Two setpoint sources
for the PID-control. Selectable with digital input
•
PID setpoint boost function
•
Feedforward function
to improve the response to the process changes
•
Process value supervision
•
Maintenance
counter
Содержание 100X series
Страница 1: ...vacon 100 x ac drives Solar pump application manual ...
Страница 2: ......
Страница 6: ...vacon 3 Vacon 100X Solar Pump Application 1 ...
Страница 8: ...2 vacon 5 Safety ...
Страница 59: ...User Interfaces vacon 56 Service support find your nearest Vacon service center at www vacon com 4 ...
Страница 160: ...vacon 157 Parameters 6 ...
Страница 169: ...Fault vacon 166 Service support find your nearest Vacon service center at www vacon com 7 ...
Страница 170: ...7 vacon 167 Fault ...
Страница 171: ......