NOTE!
If you start the application wizard from the Start-up wizard, the wizard goes directly
to step 11.
1
Set a value for P3.1.2.2 Motor Type (so that it agrees
with the nameplate of the motor)
PM motor
Induction motor
Reluctance motor
2
Set a value for P3.1.1.1 Motor Nominal Voltage (so
that it agrees with the nameplate of the motor)
Range: Varies
3
Set a value for P3.1.1.2 Motor Nominal Frequency
(so that it agrees with the nameplate of the motor)
Range: 8.00…320.00 Hz
4
Set a value for P3.1.1.3 Motor Nominal Speed (so
that it agrees with the nameplate of the motor)
Range: 24…19200 rpm
5
Set a value for P3.1.1.4 Motor Nominal Current (so
that it agrees with the nameplate of the motor)
Range: Varies
If you set Motor Type to Induction Motor, you see the next step. If your selection is PM Motor,
the value of parameter P3.1.1.5 Motor Cos Phi is set to 1.00, and the wizard goes directly to
step 7.
6
Set a value for P3.1.1.5 Motor Cos Phi (so that it
agrees with the nameplate of the motor)
Range: 0.30…1.00
7
Set a value for P3.3.1.1 Minimum Frequency Refer-
ence
Range: 0.00…P3.3.1.2 Hz
8
Set a value for P3.3.1.2 Maximum Frequency Refer-
ence
Range: P3.3.1.1…320.00 Hz
9
Set a value for P3.4.1.2 Acceleration Time 1
Range: 0.1…300.0 s
10
Set a value for P3.4.1.3 Deceleration Time 1
Range: 0.1…300.0 s
11
Select Control Place (where you give the start and
stop commands, and the frequency reference of the
drive)
I/O Terminal
Fieldbus
Keypad
The Multi-purpose application wizard is completed.
2.6
MOTOR POTENTIOMETER APPLICATION WIZARD
The application wizard helps you to set the application related basic parameters.
To start the Motor potentiometer application wizard, set the value Motor potentiometer to
parameter P1.2 Application (ID 212) in the keypad.
WIZARDS
VACON · 59
LOCAL CONTACTS: HTTP://DRIVES.DANFOSS.COM/DANFOSS-DRIVES/LOCAL-CONTACTS/