parameter descriptions
vacon
•
75
24-hour s358 (0) 201 212 575 • Email: [email protected]
9
9.4 Ramps & brakes setup (Control panel: Menu PAR -> P4)
4.1
R
AMP
S-
SHAPE
The start and end of the acceleration and deceleration ramp can be smoothed
with this parameter. Setting value 0 gives a linear ramp shape which causes
acceleration and deceleration to act immediately to the changes in the refer-
ence signal.
Setting value 0.1…10 seconds for this parameter produces an S-shaped accel-
eration/deceleration. The acceleration and deceleration times are determined
with parameters 4.2 and 4.3.
P4.2, 4.3
[Hz]
[t]
P4.1
P4.1
Figure 9.7: S-shaped acceleration/deceleration
4.2 A
CCELERATION
TIME
1
4.3
D
ECELERATION
TIME
1
4.4
R
AMP
S-
SHAPE
2
4.5
A
CCELERATION
TIME
2
4.6
D
ECELERATION
TIME
2
These limits correspond to the time required for the output frequency to ac-
celerate from the zero frequency to the set maximum frequency, or to decel-
erate from the set maximum frequency to zero frequency.
The user can set two different acceleration/deceleration time and set two dif-
ferent ramp s-shape for one application.The active set can be selected with
the selected digital input (par. 5.11).
4.7
F
LUX
BRAKING
Instead of DC braking, flux braking is a useful form of braking with motors of
max. 15 kW.
Содержание 10
Страница 1: ......
Страница 17: ...14 vacon installation Tel 358 0 201 2121 Fax 358 0 201 212205 3 MI1 MI3 3P 230 V POWER LOSS ...
Страница 18: ...installation vacon 15 24 hour support 0 201 212 575 Email vacon vacon com 3 ...
Страница 19: ...16 vacon installation Tel 358 0 201 2121 Fax 358 0 201 212205 3 MI1 MI3 1P 230 V POWER LOSS ...
Страница 20: ...installation vacon 17 24 hour support 0 201 212 575 Email vacon vacon com 3 ...