3 Appliance description
Interrupting or aborting the function test
The function test can be interrupted in 2 ways:
1. Open the appliance door.
–
In the display appears:
Pause function test
Close appliance door
–
After closing the appliance door, in the display ap-
pears:
Function test complete
or
2. Press the
button.
–
In the display appears:
Pause function test
end
continue
Aborting the function test:
–
In the display appears:
Pause function test
end
continue
▸ Press the
button.
–
In the display appears:
Function test complete
The appliance can only be operated after standing in the
normal operating position
for around 2 hours.
2.5
Where is the identification plate?
1
Identification plate with serial number (FN)
Note down the serial number (FN) of your appliance on the back page of these operat-
ing instructions.
3
Appliance description
3.1
Appliance overview
The appliance operates with a closed air circuit. Moisture is extracted from the air with
the help of a heat pump and then the air is reheated. Recovering heat in this way sharply
reduces energy consumption.
Thanks to the heat pump, the appliance dries at lower temperatures.
All the programmes are therefore gentler on your laundry. The condensate water collec-
ted is discharged through an outlet at the rear into the drainage system.
As a general rule, rooms containing a heat pump dryer must be ventilated as these pro-
duce some humidity. If the room is kept closed, it should be aired occasionally (either by
opening the door to the room or a window) between several consecutive drying pro-
grammes.
8