Installation instructions

Glass ceramic hob Toptronic
Frameless, for flush installation

J001.123-1

11.10.13  

1

 

These installation instructions apply to the model: 

001

 (GK45TE.1F), 

977

 (GK45TEASF), 

31005

 (GK45TERSF spec.)

 

Identification plate

The identification plate is next to the connection plate.

A

Affix the second identification plate (enclosed) in an accessible position behind the 
front of the fitted cabinet beneath the appliance.

A

Information on the necessary mains voltage, type of current and fuse protection can be taken from the identification plate.

A

The appliance is equipped with a mains cable that should be connected to a distribution box by the customer. For pyrometric reasons
the connection cable is not to be exchanged.

The appliance should be installed by qualified personnel only. Each step must be carried out and checked in full in the order 
specified.

Application height of the appliance: up to max. 2000 m above sea level

Validity

General notes

If fitting in flammable material, the guidelines and standards for low voltage installations and for the fire protection must be
strictly observed.

Installation accessories included

Designation

Art. no.

Cementing-in instructions

J004.133

Sealing strip set

H6.2142

Accessories

Designation

Art. no.

Steel angle set

for GK45TE.1F
for GK45TEASF, GK45TERSF spec.

H6.2084
H6.2085

Thermal screen set

for GK45TE.1F
for GK45TEASF
for GK45TERSF spec.

H6.2540
H6.2617
H6.2534

Instant adhesive for the installation of the steel angle

Permabond F246, incl. Activator, 50 ml tube. From Silitech AG, 3008 Bern.

B11.502

Cement set

Complete with cleaning agent, primer type 1105, cartridge with silicon adhesive, black with nozzle.
Suitable for all absorbent work surface materials (wood and natural stones such as marble and granite).

86.3928.85

Special primer type 107

Suitable for non-absorbent work surface materials (not suitable for polyethylene, polypropylene or Teflon).

45.2771.76

Electrical connections

Electrical connections must be carried out by trained electricians in accordance with the guidelines and standards for low
voltage installations and the specifications of the local electricity supply companies.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An
all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and
socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching
are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and
fault-free operation. After installation, live parts and cables with basic insulation must not be accessible. Old installations should
always be checked.

Connection plate

Identification plate

230 V~

PE/ green/yellow

N blue

L1 brown

400V 2N~

PE/ green/yellow
N blue

L1 brown
L2 black

600/550

Installation pipe

Clamp

Distribution box

400V~ 3

PE/

 yellow/green

L3 grey

L2 black

L1 brown

yellow/green

grey

black
brown

PE/

400V~ 2

)

L1

L2