background image

7 Technical data

7.1 

Product fiche

In accordance with EU Regulation No. 65/2014 and No. 66/2014.

Description

Abbreviations

Unit

Value

Brand

S

-

V-ZUG LTD

Model identifier

M

-

AW2T-62032

Annual Energy Consumption

AEC

hood

kWh/a

47.5

Energy Efficiency Index

EEI

hood

%

47.2

Energy Efficiency Class

EEC

-

A

Fluid Dynamic Efficiency

FDE

hood

%

34.2

Fluid Dynamic Efficiency Class

FDEC

-

A

Lighting Efficiency

LE

hood

lux/W

76.1

Lighting Efficiency Class

LEC

-

A

Grease Filtering Efficiency

GFE

hood

%

65.1

Grease Filtering Efficiency Class

GFEC

-

D

Air flow at minimum speed

Q

min

m

3

/h

300

Air flow at maximum speed (intensive or
boost excluded)

Q

max

m

3

/h

535

Air flow at intensive or boost setting

Q

boost

m

3

/h

720

Airborne acoustical A-weighted Sound Power
Emissions at minimum speed

SPE

min

dBA

50

Airborne acoustical A-weighted Sound Power
Emissions at maximum speed

SPE

max

dBA

62

Airborne acoustical A-weighted Sound Power
Emissions at intensive or boost setting

SPE

boost

dBA

70

Measured power consumption of off mode

P

0

W

Measured power consumption of standby
mode

P

s

W

0.49

Time increase factor

f

-

0.8

Measured air flow rate at the best efficiency
point

Q

BEP

m

3

/h

410

Measured air pressure at the best efficiency
point

P

BEP

PA

450

Measured value of the electric power input at
the best efficiency point

W

BEP

W

150

Nominal power of the lighting system

W

L

W

5

Average illumination of the lighting system
over the cooking surface

E

middle

lux

381

Sound power level

L

wa

dBA

62

16

Содержание AiroClearWall V2000 V90

Страница 1: ...Operating instructions AiroClearWall V2000 V90 Range hood...

Страница 2: ...afety precautions Modifications Text diagrams and data correspond to the technical standard of the appliance at the time these operating instructions went to press The right to make technical modifica...

Страница 3: ...lements 8 3 Operating the appliance 8 3 1 Operation 8 3 2 Intensive level 9 3 3 Illumination 9 3 4 Saturation indicators 9 3 5 Stand by 9 4 Care and maintenance 10 4 1 Cleaning the housing 10 4 2 Meta...

Страница 4: ...iance and have understood the haz ards involved Children shall not play with the appliance Cleaning and user mainten ance shall not be undertaken by children without supervi sion If an appliance is no...

Страница 5: ...uctions may cause a fire hazard Do not flamb food under neath the range hood 1 4 Instructions for use Before using for the first time The appliance must be installed and connected to the electricity s...

Страница 6: ...means When cleaning the appliance make sure no water gets inside it Use a mod erately damp cloth only Do not spray the inside or outside of the appliance with water Do not use a steam cleaner If water...

Страница 7: ...cooking area are passed through an activated charcoal filter The filtered air is then circulated back into the room through the side openings If activated charcoal filters are not supplied with the a...

Страница 8: ...ee seconds The stand by mode is activated The button illuminates Pressing the or button switches the appliance on at power level 1 2 3 or in tensive The corresponding button illuminates to indicate wh...

Страница 9: ...etal grease filters The button flashes after 40 operating hours The saturation level has been reached and the grease filters must be cleaned Saturation indicator for the activated charcoal filters The...

Страница 10: ...inside next to the grease filters Clean using a slightly damp cloth and detergent if necessary and wipe dry 4 2 Metal grease filter The filters can be cleaned Removing Swing the glass panel 1 up Press...

Страница 11: ...er display Activating the activated charcoal filter display Only activate this function with the recirculation model To deactivate the stand by mode Hold the button depressed for three seconds Then de...

Страница 12: ...e filter 3 forwards and lift it out of the bracket 4 1 2 3 4 Remove the activated charcoal filter 7 7 Replacing The standard activated filters cannot be washed or regenerated and are replaced As soon...

Страница 13: ...f the long life activated charcoal filter is up to three years Disconnect the power supply and switch off the fuse or circuit breaker Cleaning and regenerating Take the activated charcoal filter mat o...

Страница 14: ...ough air Possible cause Solution Metal grease filters are dirty Clean metal grease filters Only for recirculation model The activ ated charcoal filters are saturated Replace the activated charcoal fil...

Страница 15: ...tion model Activated charcoal filter for recirculation model Long life activated charcoal filter set with plastic receptacle for recirculation model Long life activated charcoal filter for recirculati...

Страница 16: ...535 Air flow at intensive or boost setting Qboost m3 h 720 Airborne acoustical A weighted Sound Power Emissions at minimum speed SPEmin dBA 50 Airborne acoustical A weighted Sound Power Emissions at m...

Страница 17: ...carried out by a qualified electrician Then cut the mains cable off flush with the appliance 8 3 Disposal The crossed out wheeled bin symbol requires the separate collection of waste electrical and e...

Страница 18: ...oving 10 Model designation 2 O Operating elements 8 Operating the appliance 8 Operation 8 P Product fiche 16 Q Queries 19 R Recirculation model 7 Resetting the filter saturation indicator 9 S Safety p...

Страница 19: ...hem on the identification plate of your appliance My appliance information SN __________________________ Appliance ______________________________ Please have this appliance information to hand when co...

Страница 20: ...grease filter saturation indicator for filter Flashing Saturation indicator for activated charcoal filters recirculation model de pending on use Replace standard activated charcoal filters Clean and...

Отзывы: