background image

4 Care and maintenance

Resetting the saturation indicator

With the appliance switched on, hold the 

 button depressed for 3 seconds to reset the

saturation indicator.
▸ The 

 (power level) and   (intensive level) displays illuminate for 2 seconds if reset

correctly.

If both the 

 and   displays are flashing after the reset, the reason for this is: the

metal grease or activated charcoal filters are also dirty and must be cleaned or re-
placed.

4.3 

Long-life activated charcoal filter

The long-life activated charcoal filter must be cleaned and reactivated bimonthly with nor-
mal use or whenever the saturation indicator flashes. If properly cared for, the service life
of the long-life activated charcoal filter is 3 years.

Disconnect the appliance from the mains and unscrew the fuse for the appliance
or switch off the circuit breaker.

Removing

▸ Pull the deflector plate completely out

and remove both grease filters.

▸ Push bar 

1

 and move the activated

charcoal filter unit 

2

 down and out of

the bracket.

▸ Remove the activated charcoal filter

mat 

3

 from its frame 

4

.

1

2

4

3

Cleaning and reactivating

▸ Clean the activated charcoal filter mat 

3

 in the dishwasher.

▸ Select an «intensive» or «heavy» dishwasher programme with a warm prewash. Wash

separately so that no food debris can become stuck to the activated charcoal filter
mat filter 

3

.

13

Содержание AiroClearCabinet V400

Страница 1: ...Operating instructions DFSE 5 6 AiroClearCabinet V400 Range hood...

Страница 2: ...he time these operating instructions went to press The right to make technical modifications for the purpose of the further development of the appliances is reserved Validity The model number correspo...

Страница 3: ...Switching the appliance on 9 3 3 Extractor fan 9 3 4 Intensive level 10 3 5 After running time 10 3 6 Illumination 10 3 7 Switching the appliance off 10 3 8 Saturation indicator 11 4 Care and mainten...

Страница 4: ...or lack of experi ence and or knowledge provided they are supervised or have been instructed on the safe use of the appliance and have understood the haz ards involved Children shall not play with the...

Страница 5: ...it chen and to achieve optimal air extrac tion Avoid a cross current of air which could blow the cooking vapours over the cooking area If other appliances fired by gas or other fuels are being used at...

Страница 6: ...e electricity supply to the appliance remove the screw fuse from the holder or switch the circuit breaker off or disconnect from the mains supply How to avoid damaging the appliance Observe the cleani...

Страница 7: ...eing filtered through the metal grease filters the cooking fumes and smells above the cooking area are passed through an activated charcoal filter The filtered air is then circulated back into the roo...

Страница 8: ...tching the extractor fan off reducing the power level Switching the extractor fan on increasing the power level Power level display Intensive level display Switch illumination on off Reset after runni...

Страница 9: ...uration indicator for the activated charcoal filter Switch the appliance off Hold the and buttons depressed for 3 seconds Power level 1 flashes in the display The appliance is now configured for the e...

Страница 10: ...ted the display flashes according to the table below and then switches off automatically Level After running time 1 20 minutes 2 15 minutes 3 10 minutes Intensive 5 minutes 3 6 Illumination Press the...

Страница 11: ...ate this function if the appliance is being used in the recirculation mode 4 Care and maintenance 4 1 Cleaning the housing Take care that no water gets into the housing of the appliance If water gets...

Страница 12: ...fixture Clean the grease filter 3 2 3 1 Cleaning Clean the grease filters 3 in the dishwasher Select an intensive or heavy wash programme with a warm prewash Cleaning may cause the metal grease filter...

Страница 13: ...mal use or whenever the saturation indicator flashes If properly cared for the service life of the long life activated charcoal filter is 3 years Disconnect the appliance from the mains and unscrew t...

Страница 14: ...an be disposed of in the household waste or at a suitable recycling point Installing Insert the activated charcoal filter mat 3 into the frame 4 Insert the activated charcoal filter unit 2 into the br...

Страница 15: ...it breaker Removing Installing Pull the deflector plate completely out and remove both grease filters Push bar 1 and move the activated charcoal filter unit 2 down and out of the bracket Replace and d...

Страница 16: ...n the power supply Check the power supply LED light bulb is defective Contact Customer Services the appliance is not extracting enough air Possible cause Solution The metal grease filters are dirty Cl...

Страница 17: ...gnation of the accessory or spare part when ordering parts Metal grease filters Long life activated charcoal filter Standard activated charcoal filter 7 Technical data Electrical connection See identi...

Страница 18: ...D Air flow at minimum speed Qmin m3 h 240 0 205 0 Air flow at maximum speed intensive or boost excluded Qmax m3 h 515 0 310 0 Air flow at intensive or boost setting Qboost m3 h 625 0 410 0 Airborne a...

Страница 19: ...dents caused by improper use e g through children playing Disconnect the appliance from the mains With a fixed appliance this is to be carried out by a qualified electrician Then cut the mains cable o...

Страница 20: ...itial set up 5 Intensive level 10 M Model designation 2 Model number 2 N Notes 21 O Operating elements 8 24 Operating the appliance 9 P Product fiche 19 Q Queries 23 R Recirculation mode 7 S Safety pr...

Страница 21: ...21 10 Notes...

Страница 22: ...22...

Страница 23: ...identification plate of your appliance My appliance information SN __________________________ Appliance _______________________________ Please have this appliance information to hand when contacting...

Страница 24: ...n on increasing the power level Power level display Intensive level display Switch illumination on off Reset after running time saturation indicator V ZUG Ltd Industriestrasse 66 CH 6302 Zug Tel 41 58...

Отзывы: