TM-50XL Quick Start Guide
D291720.6a
Page 2 of 4
Rev. 1, 6/7/17
Assembly
1.
Remove Support Plate
Using a 3/32” hex wrench, remove the (4) 4-40x1/2 SHCS from the
Support Plate
(1a)
attached to the
Loading Track
(1b)
.
Remove the support plate and discard it and the screws.
Insert the (4) 4-40x1/4 FHCS provided into the loading track where the support plate screws
had been and tighten them using a 1/16” hex wrench.
2.
Attach the Cover Tape Arm
Using a 3/16” hex wrench, remove the (2) 1/4” SHCS located on the backside of the loading
track. Bolt the
Cover Tape Arm
(2a)
to the track support bracket.
There are two amplifiers located on the back of the loading track. Lift the top of the
Amplifier
(2b)
which is closest to the track. Push the small grey switch which is inside UP. Insert the
double-pronged fiber optic cable from the cover tape arm
into the matching opening in the
amplifier. Push the gray switch down and close the amplifier top.
3.
Attach the Take-up Arm
Remove the black knob from the left side of the track support bracket. The take-up support arm
has a dowel pin which locks into position holes on the track support bracket. Slide the
Take-Up
Support Arm
(3)
onto the threaded rod, engaging the dowel pin into the desired position.
Secure the arm in place by tightening the black knob.
Plug the electrical connector into the take-up motor receptacle.
4.
Attach the Payout Arm
Remove the black knob from the right side of the track support bracket. The
Payout Arm
(4)
has a dowel pin which locks into position holes on the track support bracket. Slide the payout
arm onto the threaded rod. Engage the dowel pin into the desired position and secure the arm
in place by tightening the black knob.
5.
If using the
Empty Pocket Detector
(EPD)
(5a)
, plug the EPD cable into the
EPD
Receptacle
(5b)
on the left side of the sealer assembly.
6.
Install Air Regulator
Attach the
Air Regulator
(6)
to the back of the sealer controller with the provided screws.
Attach the open end of the blue air hose to the right side of the controller. Connect an airline to
the air regulator and set the regulator to
85 psi
. It can be adjusted by lifting the adjustment
knob and turning it. Once it reads 85 psi, push the knob back in to lock it in place.
Note:
An air supply is only necessary for the operation of the heat sealer.
Suggested settings are between 85-110 psi.
1a
1b
2a
4
3
2b
5a
5b
6