Tips on Part Placement
Chapter 7: Troubleshooting
7-21
Tips on Part Placement
If components are not dropped properly, there are four variables that can be adjusted to correct
the problem.
Note:
Each part is different and may require a different combination of adjustments to
obtain proper place performance.
1.
Adjust Blow-off Pressure.
The
Blow-off Pressure
Gauge
is
located on the front of the
Pick Head enclosure
. If components
are not dropping properly, loosen locking nut and rotate to adjust
pressure levels. When the desired pressure level is reached,
tighten locking nut.
Note:
Every part is different and may require a different combi-
nation of adjustments to obtain proper place performance.
2.
Adjust Place Position X
. Open the HMI
Head Tab
. Press the
Move To Place
button