7-12
TM-403 User’s Guide
System Alarm Messages
D292106.9b.fm
Temperature Out of Range System Alarm
When
Heat Seal
is enabled and the
Heat Shoe
temperatures are either too hot or too cold, a
Heat Seal Temperature Out of Range
system alarm will activate.
When this occurs,
tape advance stops, a beep sounds and a warning appears on the HMI.
To clear the
Heat Seal Temperature Out of Range
System Alarm
, wait for the heat shoes to
reach their set point and then press
CONTINUE
to clear the alarm and resume operation.