Part Lost System Alarm
If a part falls off the nozzle and is lost during the Pick process, the
Part Lost
system alarm will be
activated. When this happens, operation stops, a beep sounds, and a warning appears on the
HMI.
To clear the
Part Lost System Alarm,
check the
Vacuum Sensor
to ensure it is set correctly. Next,
ensure the correct
Nozzle Tip
for the part that is being picked is installed. Finally, check the
Pick
Position
to ensure it is centered correctly. Adjust as necessary.
When the
Tray Feeder
is ready for operation, press
CONTINUE
to clear the alarm and resume
operation.