5-26
TM-403 User’s Guide
Configure Inspection
D292106.16c.fm
A
Statistics Graph
of all test results will appear in the lower right corner.
14.
On the TM-403 HMI, open the
Taper Tab
. Press the right
Arrow
button to advance
to the second
Taper
screen.
Press
Trigger
to manually trigger an inspection of the part under the camera. The
green
PASS
message should appear. Test several good parts to ensure TM-403
correctly and consistently passes good parts.