4-28
TM-403 User’s Guide
Test Seal
D292106.7b.fm
Test Seal
Perform a
Seal Test
to ensure a good seal. Adjust
Sealer
settings in the HMI
Taper
tab as
necessary.
1.
Run the tape through the taping module by pressing the
Continuous Advance
button in the HMI
Taper Tab
.
2.
As the seal is occurring, watch the alignment of the cover tape with the carrier
tape. The cover tape should run exactly in the groove of the cover tape guide and
the seal should appear as a solid, consistent line. If the seal width is incorrect, stop
the
Taper
by pressing the
Continuous Advance
button again.
3.
Adjust the seal positions as necessary. The sealer’s inside and outside seals are
independently adjustable. If one of the seals needs to be moved, loosen the
Step 7:
Seal Test