background image

C O N T E N T S

1.

INSTALLATION

2.

SPECIFICATIONS

3.

KEYBOARD LAYOUT AND DESCRIPTION

4.

INITIAL SETUP

5.

INSTRUCTION FOR USE

6.

TROUBLE SHOOTING

7.

DAILY CARE AND MAINTENANCE

APPENDIX

Installation Diagram

Installation Procedures

DECEMBER 1999

Specifications subject to change without prior notice

PS SERIES

All STAINLESS STEEL BENCH SCALE

O P E R A T I O N

M A N U A L

PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE

ATTEMPT TO OPERATE THE SCALE

This document hosted by: www.oldwillknottscales.com

Содержание PS SERIES

Страница 1: ... DAILY CARE AND MAINTENANCE APPENDIX Installation Diagram Installation Procedures DECEMBER 1999 Specifications subject to change without prior notice PS SERIES All STAINLESS STEEL BENCH SCALE OPERATION MANUAL PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE SCALE This document hosted by www oldwillknottscales com ...

Страница 2: ...r any problem in installation contact your dealer 1 3 Power on the scale a Before plugging the power adaptor into electricity outlet check and make sure that the input voltage of power adaptor matches with the output voltage of the b Before first time use plug the main adaptor into the wall outlet and charge the scale for at least 8 hours c Retain the packing materials for future transportation pu...

Страница 3: ...o range Up to 2 rated capacity Weight Units Metric decimal pound Note A and pound ounce Operation 0o 40o C 32o 104o F Environment Non condensed R H 85 Specifications subject to change without notice Note A To comply with the law of certain countries the avoirdupois weight units may be disabled Contact your dealer for more information 1 ON OFF KEY Press this key to turn scale on or off 2 MODE KEY P...

Страница 4: ... arrow will appear and point at this sign when memory contains of accumulated data 11 WEIGHT UNIT INDICATOR kg indicates the metric unit is being employed lb indicates the avoirdupois unit is being employed 12 LO BAT INDICATOR When this indicator appears recharge the scale immediately Failure to do so may cause unrecoverable damages to the built in rechargeable battery 13 IN CHARGE INDICATOR Red c...

Страница 5: ...avoirdupois weight units Follow the below steps to enable disable the avoirdupois units a Turn scale off b Press and hold TARE then press ON OFF c Scale displays F 1 4 2 2 Select Auto Power Off Setting The scale is equipped with Auto Power Off Function The scale will be turned off automatically if it is not used for 4 minutes Follow the below steps to enable disable the Auto Power Off Function a T...

Страница 6: ...essive force applied to platform may cause damages to sensor inside b The weight of the object would be displayed automatically c It is a good practice to remove all loads from platform after weighing It would prolong the lifetime of scale 5 3 Select Weight Unit e Scale displays F 4 f Press MODE to shift between 0 _OFF and 4 _OFF g To enable the Auto Power Off Function press ZERO when 4 _OFF appea...

Страница 7: ...Press MODE to shift among kg ...

Страница 8: ...d weight is being displayed Scale will display P 0 to indicate all data in memory has been erased Caution All data stored in memory will be erased if a The scale is turned off or b The weight unit is changed 5 9 Recharge the Scale The scale is equipped with a built in rechargeable battery When LO BAT INDICATOR appears recharge the scale immediately Failure to do so may cause unrecoverable damages ...

Страница 9: ...Action Secure both ends of the power adaptor and try again Syndrome Check Action Check Action Syndrome Check Action Rated capacity cannot be reached Is the TARE INDICATOR on Turn the scale off Remove all loads from platform and turn on again Is there anything obstructing the platform or pillar Remove all obstacles Scale displays 00000 Does the load applied to platform excess the rated capacity of ...

Страница 10: ...unit settings and usage 7 DAILY CARE AND MAINTENANCE Clean the scale with a soft and damp cloth If necessary apply a mild detergent Do not use any high pressure water spray harsh abrasive material acetone volatile solvent thinner or alcohol for cleaning 7 3 Verify the accuracy of scale periodically Re calibrate the scale if necessary Note In some countries calibration is restricted to be done by a...

Страница 11: ... the platform very carefully 2 Thread the cable through the pillar 3 Lift the pillar to upright position 4 Fix the pillar to the platform base firmly using the screws provided 5 Fix the indicator to the indicator mounting using the screws provided 6 Plug the cable plug into the indicator firmly ...