Страница 3: ... for trade only when it is sealed and or stamped and bearing a serial number Do not attempt to break the seal or stamp affixed to this indicator or remove the serial number Contact your dealer for more information and after sales service For most accurate weighing result do not use the indicator in where or when the environment condition falls beyond as those listed on SPECIFICATIONS Do not attemp...

Страница 4: ...RNAL POWER ADAPTOR OR RECHARGEABLE BATTERY Minimum battery voltage 5 5 VDC Load cell Excitation voltage 5 VDC Minimal load cell impedance 85 Maximal load cell impedance 5000 Load cell connection 4 wire Operation Environment 10o 40o C Non condensed R H 85 Specifications subject to change without notice NOTE 1 For Multi range or interval change e to e1 CAUTION To comply with the law of certain count...

Страница 5: ...hift among different weight units and or turn backlight on off 3 TARE KEY Press this key to tare off the weight of a container 4 ZERO KEY Press this key to set weight displayed to zero 5 M KEY Press this key to accumulate current weight to memory 6 MR KEY Press this key to recall the total accumulated weight from memory ...

Страница 6: ...This indicator appears to indicate zero weight status 10 NET INDICATOR This indicator appears to indicate the tare function is in operation and weight shown is net weight 11 M INDICATOR This indicator appears to indicate memory contains of stored data 12 MR INDICATOR This indicator appears to indicate the value shown is the total accumulated weight stored 13 WEIGHT UNIT INDICATOR The current weigh...

Страница 7: ...irdupois weight units Default setting metric weight unit only Follow the below steps to enable disable the avoirdupois units a Turn indicator off b Press and hold TARE then press ON OFF c Indicator displays F 1 d Press TARE twice e Indicator displays F 3 f Press and hold MODE until the kg or lb sign appears g Press MODE to shift between kg and lb sign To enable the avoirdupois units press TARE whe...

Страница 8: ...o Power Off Function The indicator will be turned off automatically if it is not used for 4 minutes Follow the below steps to enable disable Auto Power Off Function a Turn indicator off b Press and hold TARE then press ON OFF c Indicator displays F 1 d Press TARE three times e Indicator displays F 4 f Press MODE to shift between 0 _OFF and 4 _OFF To enable Auto Power Off Function press TARE then Z...

Страница 9: ...lay to zero 5 2 WEIGHING a Always place an object onto the scale gently Excessive force applied to platter may cause damages to weight sensor b The weight of the object is displayed on the indicator automatically c It is a good practice to remove all loads from scale after weighing It would prolong the lifetime of weight sensor 5 3 SELECT WEIGHT UNIT Press MODE to shift among kg decimal lb oz kg w...

Страница 10: ...remained for 25 seconds or a zero weight is detected and remains stable for 10 seconds Backlight will be automatically turned on again when a new weight is detected or when any key is pressed 5 5 SET DISPLAYED VALUE TO ZERO WHEN UNLOADED By pressing ZERO weight displayed will be set to zero and ZERO INDICATOR appears Refer to SPECIFICATIONS for maximum zero range 5 6 TARE OFF THE WEIGHT OF A CONTA...

Страница 11: ...IFICATIONS for maximum tare range 5 7 CLEAR THE TARE FUNCTION Remove all loads from scale then press TARE After TARE is pressed the TARE INDICATOR would disappear 5 8 MEMORY FUNCTION 5 8 1 Accumulate a Transaction To Memory a Refer to 5 2 for weighing producers b Press M to save and accumulate data of current transaction to memory c Indicator displays P 1 and M INDICATOR appears to indicate that m...

Страница 12: ...d then a flashing value The flashing value is the total accumulated weight stored in memory When the total accumulated weight is being displayed MR INDICATOR appears to indicator that the value being displayed is the accumulated weight Indicator returns to normal display status after 3 seconds 5 8 3 Memory Clear All transactions stored in memory by pressing MR and ZERO simultaneously CAUTION All d...

Страница 13: ...echargeable is Used The indicator will be power off in about 5 to 10 minutes Recharge the battery now 5 9 2 In case a Power Adaptor is Used Check power supply to indicator immediately NOTE If LO BAT status is detected during power on indicator shows P OFF and the indicator will be powered off automatically ...

Страница 14: ...to disable Auto Power Off Function Check Is the LO BAT INDICATOR on Action Check power supply Syndrome Rated capacity cannot be reached Check Is the TARE INDICATOR on Action Turn the indicator off Remove all loads and turn on again Check Is there anything obstructing the scale Action Remove all obstacles Syndrome Blank display with only kg or lb Check Is the load applied to scale excess the rated ...

Страница 15: ... cell working properly Action Check load cell input output Syndrome Weighing result is not accurate Check Is the scale placed in a level condition Action Obtain a level condition Check Is the scale affected by airflow vibration or RFI Action Place the scale away from all disturbances Check Is the indicator calibrated correctly Action Contact your dealer ...

Страница 16: ...y harsh abrasive material acetone volatile solvent thinner or alcohol for cleaning 7 3 Verify the accuracy of indicator periodically Re calibrate the indicator if necessary NOTE In some countries calibration requires authorized qualified agent Contact your dealer for more information 7 4 Store indicator scale in a dry and clean place ...

Страница 17: ...ator will shut off after this message appeared Error Error during calibration Case 1 The 1st calibration weight entered is less than 1 3 of rated capacity Case 2 The 2nd calibration weight entered is over the rated capacity Case 3 The span value is not within the acceptable range ...