![Utimaco CryptoServer LAN V4 Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/utimaco/cryptoserver-lan-v4/cryptoserver-lan-v4_operating-manual_1065531041.webp)
Technical Data of CryptoServer LAN V4 (DC Power Supply)
Page 41 of 42
8
Technical Data of CryptoServer LAN V4 (DC Power Supply)
Dimensions
Height
88 mm (2 slots (height units))
Width
446 mm without attachment bracket (19”)
Depth
472 mm excluding handles
Weight
13 kg
Operating power
42 V ~ 60 V DC
Power supply
2 x 350 W
Power consumption
Typically 80 W, maximum 95 W
Heat dissipation
324 BTU/h
Environmental
temperature
in operation
CryptoServer Se-Series Gen2: +10 °C to +50 °C
CryptoServer CSe-Series: +10 °C to +40 °C
in storage
-10 °C to +55 °C (+14 °F to +131 °F)
Humidity
10% to 95% relative humidity, non-condensing
MTBF
90.000 hours at 25 °C/77 °F (in acc. with MIL-HDBK-217)
RoHS compliance
Yes
WEEE
National register for waste electric equipment (EAR) DE39805015
Conformity
EMC emission: CISPR 22 / CISPR 32 Class A
EMC immunity: EN 300386, EN 55024 / CISPR 24, IEC/EN 61000-6-2
Equipment safety: IEC/EN 60950-1 (CB scheme)
FCC 47 CFR Part 15 Class A
UL
Climatic and mechanical conditions: EN 300 019: Storage class 1.1,
Transportation class 2.1 (with temperature range restricted to the storage
environmental temperature given above), stationary use in environments
that are protected from the weather class 3.1
Содержание CryptoServer LAN V4
Страница 1: ...CryptoServer LAN V4 Operating Manual...