DETECTOR TESTING
1. On the Iris Web site,
activate Test Mode for the
detector and follow the
on-screen instructions.
When instructed, press
the button on detector (A)
three
times
.
SPECIFICATIONS
Operating Temperature:
32° to 120° F (0° to 49° C)
Operating Relative Humidity:
5 to 95%, non-condensing
Sensor Type:
Single microphone, dual-stage, detector
listens for “thud” then “shatter” glass breaking sounds.
Indicators:
Green = “thud”, red = “shatter” detection.
Glass Thickness:
1/8 in. (3.2 mm) to 1/4 in. (6.4 mm)
HELPFUL TIPS
•
Glass to be monitored for breakage must be at
least 11 in. x 11 in. (28 cm x 28 cm) square. Glass
must be framed, in a wall of the room or mounted in
a barrier of 36 in. (91 cm) minimum width.
•
The detector will not lock onto the mounting plate
unless both CR123A batteries are installed.
•
The detector communicates with the Iris hub using
Z-Wave
®
radio signals.
WARRANTY
Linear LLC (the Company) warrants to the original purchaser that products delivered hereunder will be free of
defects in materials and workmanship for a period of one (1) year from the date of purchase.
The Company within said period shall at its option, either repair or replace free of charge, any product or part
thereof found, upon the Company’s inspection, to be so defective, and will return the repaired or replaced
product to the purchaser at Company’s expense.
All products returned for warranty service require a Return Product Authorization Number (RPA#). For
warranty service, shipping instructions, and an RPA#, contact Linear Technical Services at 1-855-546-3351.
Devices must be sent to the Company at owner’s expense and be accompanied with statement of defect and
proof of purchase. This warranty is conditioned on the following:
• The Company must be notifi ed within one year of purchase and have been given the opportunity of
inspection by return of any alleged defective product free and clear of all liens and encumbrances to the
Company or its distributor; and
• The product must not have been abused, misused or improperly maintained and/or repaired during such
period; and
• Such defect has not been caused by corrosion or exposure to other than ordinary wear and tear.
THE COMPANY MAKES NO OTHER WARRANTY OR REPRESENTATION OF ANY KIND WHATSOEVER INCLUDING ANY
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED.
The Company’s maximum liability hereunder is limited to the purchased price of the product. In no event shall
the Company be liable for any consequential, indirect, incidental or special damages of any nature arising
from the sale or use of the product, whether based in contract, tort, strict liability or otherwise.
Note: Some states do not allow limitations on incidental or consequential damages or how long an implied
warranty lasts, so that the above limitations may not fully apply. This warranty gives specifi c legal rights and
you may also have other rights which may vary from state to state.
Changes or modifi cations to the device may void FCC compliance. Les modifi cations apportées à l’appareil
peuvent annuler la conformité Industrie Canada.
Z-Wave® is a registered trademark of Sigma Designs Inc. and/or its subsidiaries.
PAIRING WITH IRIS
1. Install two batteries (CC) into
the detector (A).
Observe
polarity!
2. Go to
www.lowes.com/iris
3. From the Iris Web site, click
“DEVICES”, then click the
“ADD DEVICES” button.
4. Select Glass Break Detector
from the list.
5. Follow the on-screen
instructions to pair the
detector with the hub.
6. When instructed, press the
button on the detector (A).
MOUNTING THE DETECTOR
1. Choose a location on the
ceiling or on an adjacent or
opposite wall within 12 ft. of
the glass to be monitored.
Use the mounting plate (B) as
a template to mark the three
mounting holes.
2. Drill three 3/16 in. pilot holes
and insert screw anchors
(BB). Attach mounting plate
(B) with three mounting
screws (AA).
3. Match alignment marks on
detector (A) and mounting
plate (B). Turn detector
(A) clockwise to lock onto
mounting plate (B).
ITEM #0567900
MODEL #GB00Z-1
GLASS BREAK DETECTOR
Questions?
Call customer service at 1-866-994-4148,
8 a.m. - 6 p.m., EST, Monday - Thursday
8 a.m. - 5 p.m., EST, Friday
PACKAGE CONTENTS
HARDWARE CONTENTS
Note: Hardware shown actual size.
SAFETY INFORMATION
Please read and understand this entire manual before
attempting to assemble, operate, or install the product.
WARNING
Danger of explosion if batteries are installed
incorrectly. Replace only with the same or equivalent
type recommended by the manufacturer.
PREPARATION
Before beginning installation of product, make sure
all parts are present. Compare parts with package
contents list and hardware contents list. If any part
is missing or damaged, do not attempt to assemble,
install or operate the product.
Estimated Installation Time:
15 minutes.
Tools required for installation (not included):
pencil, Phillips screwdriver, drill, 3/16 inch drill bit
CC
A
A
B
B
A
A
B
AA
BB
CC
CR123A
x 3
Mounting Screw
x 3
Screw Anchor
x 2
CR123A Battery
AA
CC
BB
x 1
Mounting Plate
x 1
Detector
A
B
AB13890
Printed in China
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,GLASS BREAK,ZW - P/N: 235512 A- INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 11.000” X 8.500” - FOLDING: Z-FOLD, FINISH WITH LOGO SHOWING - SCALE: 1-1 - SIDE 1 OF 2
1
3x
1
6
2
1
3
1
2
3