background image

DETECTOR TESTING

1. On the Iris Web site, 

activate Test Mode for the 
detector and follow the 
on-screen instructions. 
When instructed, press 
the button on detector (A) 

three

 

times

.

SPECIFICATIONS
Operating Temperature:

 32° to 120° F (0° to 49° C)

Operating Relative Humidity:

 5 to 95%, non-condensing

Sensor Type:

 Single microphone, dual-stage, detector 

listens for “thud” then “shatter” glass breaking sounds.

Indicators:

 Green = “thud”, red = “shatter” detection.

Glass Thickness:

 1/8 in. (3.2 mm) to 1/4 in. (6.4 mm)

HELPFUL TIPS
• 

Glass to be monitored for breakage must be at 
least 11 in. x 11 in. (28 cm x 28 cm) square. Glass 
must be framed, in a wall of the room or mounted in 
a barrier of 36 in. (91 cm) minimum width.

• 

The detector will not lock onto the mounting plate 
unless both CR123A batteries are installed.

• 

The detector communicates with the Iris hub using 
Z-Wave

®

 radio signals.

WARRANTY

Linear LLC (the Company) warrants to the original purchaser that products delivered hereunder will be free of 
defects in materials and workmanship for a period of one (1) year from the date of purchase.
The Company within said period shall at its option, either repair or replace free of charge, any product or part 
thereof found, upon the Company’s inspection, to be so defective, and will return the repaired or replaced 
product to the purchaser at Company’s expense.
All products returned for warranty service require a Return Product Authorization Number (RPA#). For 
warranty service, shipping instructions, and an RPA#, contact Linear Technical Services at 1-855-546-3351. 
Devices must be sent to the Company at owner’s expense and be accompanied with statement of defect and 
proof of purchase. This warranty is conditioned on the following:
• The Company must be notifi ed within one year of purchase and have been given the opportunity of 

inspection by return of any alleged defective product free and clear of all liens and encumbrances to the 
Company or its distributor; and

•  The product must not have been abused, misused or improperly maintained and/or repaired during such 

period; and

•  Such defect has not been caused by corrosion or exposure to other than ordinary wear and tear.
THE COMPANY MAKES NO OTHER WARRANTY OR REPRESENTATION OF ANY KIND WHATSOEVER INCLUDING ANY 
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED.
The Company’s maximum liability hereunder is limited to the purchased price of the product. In no event shall 
the Company be liable for any consequential, indirect, incidental or special damages of any nature arising 
from the sale or use of the product, whether based in contract, tort, strict liability or otherwise.
Note: Some states do not allow limitations on incidental or consequential damages or how long an implied 
warranty lasts, so that the above limitations may not fully apply. This warranty gives specifi c legal rights and 
you may also have other rights which may vary from state to state.
Changes or modifi cations to the device may void FCC compliance. Les modifi cations apportées à l’appareil 
peuvent annuler la conformité Industrie Canada.
Z-Wave® is a registered trademark of Sigma Designs Inc. and/or its subsidiaries.

PAIRING WITH IRIS

1. Install two batteries (CC) into 

the detector (A). 

Observe 

polarity!

2. Go to 

www.lowes.com/iris

3. From the Iris Web site, click 

“DEVICES”, then click the 
“ADD DEVICES” button.

4. Select Glass Break Detector 

from the list.

5. Follow the on-screen 

instructions to pair the 
detector with the hub.

6. When instructed, press the 

button on the detector (A).

MOUNTING THE DETECTOR

1. Choose a location on the 

ceiling or on an adjacent or 
opposite wall within 12 ft. of 
the glass to be monitored. 
Use the mounting plate (B) as 
a template to mark the three 
mounting holes.

2. Drill three 3/16 in. pilot holes 

and insert screw anchors 
(BB). Attach mounting plate 
(B) with three mounting 
screws (AA).

3. Match alignment marks on 

detector (A) and mounting 
plate (B). Turn detector 
(A) clockwise to lock onto 
mounting plate (B).

ITEM #0567900

MODEL #GB00Z-1

GLASS BREAK DETECTOR

Questions?
Call customer service at 1-866-994-4148,
8 a.m. - 6 p.m., EST, Monday - Thursday
8 a.m. - 5 p.m., EST, Friday

PACKAGE CONTENTS

HARDWARE CONTENTS
Note: Hardware shown actual size.

 SAFETY INFORMATION

Please read and understand this entire manual before 
attempting to assemble, operate, or install the product.

 WARNING

Danger of explosion if batteries are installed 
incorrectly. Replace only with the same or equivalent 
type recommended by the manufacturer.

PREPARATION

Before beginning installation of product, make sure 
all parts are present. Compare parts with package 
contents list and hardware contents list. If any part 
is missing or damaged, do not attempt to assemble, 
install or operate the product.

Estimated Installation Time:

 15 minutes.

Tools required for installation (not included):
pencil, Phillips screwdriver, drill, 3/16 inch drill bit

CC

A

A

B

B

A

A

B

AA

BB

CC

CR123A

x 3

Mounting Screw

x 3

Screw Anchor

x 2

CR123A Battery

AA

CC

BB

x 1

Mounting Plate

x 1

Detector

A

B

AB13890

Printed in China

PRINTER’S INSTRUCTIONS:

INSTR,INSTL,GLASS BREAK,ZW - P/N: 235512 A- INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 11.000” X 8.500” - FOLDING: Z-FOLD, FINISH WITH LOGO SHOWING - SCALE: 1-1 - SIDE 1 OF 2

1

3x

1

6

2

1

3

1

2

3

Отзывы: