5
Dimensions
SYSTEM
When boiler is operating at maximum operating temperature, providing heating with all heat emitters operating, pressure gauge
should not indicate more than 26.11 psi / 1.80 bar. If reading exceeds this figure larger expansion tank is required.
2A - PHYSICAL DATA
DIMENSIONS
125 & 150
165 & 205
Height (Bottom of boiler top of safety Valve)
43.65" [1.09 m]
Overall Width with Manifold
24.70" [628 mm]
Depth
17.46" [444 mm]
Condensate Trap Connection
3/4"
NPT
System Supply
11/4” Sweat Connection
11/2” Sweat Connection
DHW Outlet (125 Optional)
(125)
3/4” Sweat
Connection
(150)
1/2” Sweat
Connection
(165)
NA
(205)
3/4” Sweat
Connection
Gas Connection
3/4” NPT
DHW (Cold Water) Inlet
(125)
NA
(150)
1/2” Sweat
Connection
(165)
NA
(205)
3/4” Sweat
Connection
System Return
11/4” Sweat Connection
11/2” Sweat Connection
Boiler Filling Connection
External to Boiler
Primary Water Content
1 gal [3.60 L]
11/4 gal [
4.73
L]
Central Heating (Sealed System)
125 / 150
165/ 205
Heat Exchanger Max Allowable Working Pressure
50 psi [3.45 bar]
Max System Pressure
30
.00
psi
[2.11 bar]
Min System Pressure
7.25
psi [ 0.50 bar]
Max System temperature
176°F
[80°C]
Pressure Relief Valve Setting
30
.00
psi [2.11 bar]
Expansion Tank Minimum Size
(pre-charge
press.)
2.2
gal at 11.6 psi [10.0
L at
0.8 bar]
Recommended System Pressure (cold)
21.7 psi [1.5 bar]
Domestic Hot Water (Sealed System)
150
205
Max Inlet Water Pressure
116 psi [8 bar]
116 psi [8 bar]
Min Inlet Water Pressure
2.9 psi [ 0.2 bar]
2.9 psi [0.2 bar]
Min DHW Flow Rate
* 0.55 gpm [2.50 L/min]
* 0.55 gpm [2.50 L/min]
Max DHW Temperature
140°F [60°C]
140°F [60° C]
DHW Water Content
0.05 gal [0.23 L]
0.10 gal [0.37 L]
* Note: Water flow rate must be .7 GPM to ignite.
240012874 REV A, [01/31/2020]
Содержание MACF-150
Страница 63: ...61 A 1 MODELS 125 Heat Only APPENDIX A WIRING DIAGRAMS 240012874 REV A 01 31 2020 ...
Страница 64: ...62 APPENDIX A WIRING DIAGRAMS A 2 MODELS 165 Heat Only 240012874 REV A 01 31 2020 ...
Страница 65: ...63 A 2 MODELS 150 Combi APPENDIX A WIRING DIAGRAMS 240012874 REV A 01 31 2020 ...
Страница 66: ...64 A 4 MODELS 205 Combi APPENDIX A WIRING DIAGRAMS 240012874 REV A 01 31 2020 ...
Страница 67: ...65 NOTES 240012874 REV A 01 31 2020 ...
Страница 68: ...66 NOTES 240012874 REV A 01 31 2020 ...
Страница 90: ...20 150F 205F WITH ZONE PUMPS WIRING DIAGRAM 150F 205F WITH ZONE PUMPS PN 240012875 REV A 01 31 2020 ...
Страница 92: ...22 150F 205F WITH ZONE VALVES WIRING DIAGRAM 150F 205F WITH ZONE VALVES PN 240012875 REV A 01 31 2020 ...
Страница 98: ...28 MODEL 125F Heat Only 125F FLOOR STANDING HEAT ONLY WIRING DIAGRAM PN 240012875 REV A 01 31 2020 ...
Страница 99: ...29 MODEL 150F Combi 150F FLOOR STANDING COMBI WIRING DIAGRAM PN 240012875 REV A 01 31 2020 ...
Страница 100: ...30 165F FLOOR STANDING HEAT ONLY WIRING DIAGRAM MODEL 165F Heat Only PN 240012875 REV A 01 31 2020 ...
Страница 101: ...31 205F FLOOR STANDING COMBI WIRING DIAGRAM MODEL 205F Combi PN 240012875 REV A 01 31 2020 ...
Страница 106: ...36 Low Water Cutoff Detail LOW WATER CUTOFF NO NO YES PN 240012875 REV A 01 31 2020 ...