![UTICA BOILERS MAC-115 Скачать руководство пользователя страница 52](http://html1.mh-extra.com/html/utica-boilers/mac-115/mac-115_manual_1065164052.webp)
48
9 - START UP PROCEDURE
9.2 Central Heating System Connections - Combi
MAC-115 & 150 COMBI
MAC-205 COMBI
LEGEND
115 & 150
205
A
Pressure Gauge
-
B
Pressure Relief Valve
30.00 psi [2.11 bar]
C
Heating return connection
3/4" [22.2 mm]
1" [25.4 mm]
D
Cold DHW inlet tap / system filling connection
for Combi
1/2"
[15.9 mm]
3/4" NPT
E
Gas shutoff connection
3/4" [22.2 mm]
F
Boiler Fast Fill
External to Boiler
NA
G
DHW outlet/indirect storage tank connection
1/2"
[15.9 mm]
3/4" NPT
H
Drain connection for condensate
13/16" [21 mm] ID
Hose
3/4 NPT
I
Heating supply connection
3/4" [22.2 mm]
1" [25.4 mm]
J
Manifold
1-1/4" (6.35 mm)
NA
K
5 gpm DHW flow restrictor
(Factory installed) (205 only)
na
3/4"
[22.2 mm]
A
B
H
I
E
C
MANIFOLD
MAC-115, 150 & 205
K
G
D
A
D
C
F
G
E
I
B
H
J
240013354 REV B [09/15/2021]
Содержание MAC-115
Страница 2: ...MAC 205 ...
Страница 4: ...MAH 165 ...
Страница 77: ...73 APPENDIX A WIRING DIAGRAMS A 2 MODEL 125 Heat Only 240013354 REV B 09 15 2021 ...
Страница 78: ...74 APPENDIX A WIRING DIAGRAMS A 3 MODEL 165 Heat Only 240013354 REV B 09 15 2021 ...
Страница 79: ...75 APPENDIX A WIRING DIAGRAMS A 1 MODEL 115 Combi 240013354 REV B 09 15 2021 ...
Страница 80: ...76 APPENDIX A WIRING DIAGRAMS A 4 MODEL 150 Combi 240013354 REV B 09 15 2021 ...
Страница 81: ...77 APPENDIX A WIRING DIAGRAMS A 5 MODEL 205 Combi 240013354 REV B 09 15 2021 ...
Страница 82: ...78 NOTES 240013354 REV B 09 15 2021 ...
Страница 118: ...34 MODEL 125 Heat Only 125 HEAT ONLY WIRING DIAGRAM PN 240011430 REV P 09 15 2021 ...
Страница 119: ...35 MODEL 165 Heat Only 165 HEAT ONLY WIRING DIAGRAM PN 240011430 REV P 09 15 2021 ...
Страница 120: ...36 115 COMBI WIRING DIAGRAM MODEL 115 Combi PN 240011430 REV P 09 15 2021 ...
Страница 121: ...37 MODEL 150 Combi 150 COMBI WIRING DIAGRAM PN 240011430 REV P 09 15 2021 ...
Страница 122: ...38 MODEL 205 Combi 205 COMBI WIRING DIAGRAM PN 240011430 REV P 09 15 2021 ...
Страница 127: ...43 Low Water Cutoff Detail LOW WATER CUTOFF NO NO YES PN 240011430 REV P 09 15 2021 ...
Страница 132: ...48 3 FAULT SOLUTION SECTIONS PN 240011430 REV P 09 15 2021 ...
Страница 135: ...51 Parameter ID Changed From Changed To Date Reason PARAMETER CHANGE HISTORY PN 240011430 REV P 09 15 2021 ...