2NM/2NX/2NY/2NZ/2P0/2P6
1-5-98
(4) Detaching and refitting the FAX control PWB (FAX model only)
Procedure
1. Remove the upper interface cover.
2. Release two hooks using a flat screw
driver and remove the right stay cover.
Figure 1-5-168
3. Remove two screws and then pull the
FAX control PWB out.
4. Check or replace the FAX control PWB
and refit all the removed parts.
Figure 1-5-169
Upper
interface cover
Flat screw driver
Right stay cover
Hooks
Screw
Screw
Fax control PWB