2NM/2NX/2NY/2NZ/2P0/2P6
1-3-67
U604
User Data 2
Description
Makes user settings to enable the use of the machine as a fax.
Purpose
Use this if the user wishes to adjust the number of rings that occur before the unit switches into fax
receiving mode when fax/telephone auto-select is enabled.
Method
1. Press the start key.
2. Select [Rings(F/P)#].
3. Change the setting using the cursor right/left keys or numeric keys.
Display
Description
Setting range
Initial setting
Rings(F/T)
Number of fax/telephone rings
0 to 15
2 (120 V)/
1 (220-240 V)
* : If you set this to 0, the unit will start fax reception without any ringing.
4. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U605
Clr Data
Description
Initializes data related to the fax transmission such as transmission history.
Purpose
To clear the transmission history.
Method
1. Press the start key.
2. Select [Comm Rec].
Display
Description
Comm Rec
To clear the transmission history.
3. Press the start key. Initialization processing starts. When processing is finished, [Completed] is
displayed.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Содержание P-4030 MFP
Страница 7: ...This page is intentionally left blank ...
Страница 13: ...This page is intentionally left blank ...
Страница 19: ...2NM 2NX 2NY 2NZ 2P0 2P6 5 Installation Guide PF 320 Paper Feeder ...
Страница 55: ...2NM 2NX 2NY 2NZ 2P0 2P6 1 2 24 This page is intentionally left blank ...
Страница 347: ...2NM 2NX 2NY 2NZ 2P0 2P6 1 5 61 Figure 1 5 103 Exit unit Screw Screws Connector Hooks Wire 40 ppm model ...
Страница 386: ...2NM 2NX 2NY 2NZ 2P0 2P6 1 5 100 This page is intentionally left blank ...
Страница 486: ...Installation Guide PF 320 Paper Feeder Installation Guide ...
Страница 487: ...PF 320 㾌㙼 㾌㙼 PF 320 PF 320 PF 320 㪧㪝㪄㪊㪉㪇 㪧㪝㪄㪊㪉㪇䈱 㪧㪝㪄㪊㪉㪇G 㾌 㾌 PF 320 PF 320 ...
Страница 488: ... For Legal Folio OficioII 1 1 1 1 2 2 2 2 ...