3NV-2
1-3-26
U099
Adjusting original size detection
Description
Checks the operation of the original size sensor and sets the sensing threshold value.
Purpose
Modify the threshold of detection if documents are frequently mal-detected in size after scanning
a wholly dark document or a document enclosed with dark objects on edges.
Method
1. Press the start key.
2. Select the item.
Method: [Data1/Data2]
1. Place the original and close the original cover or DP. The detection sensor transmission data
is displayed.
2. The light source illuminates and the CCD sensor determines the width of the document. The
original size sensor determines the document is vertical or horizontal. (The document is
detected two times when the DP is installed.)
Item No.
Description
Display
Description
Data1
Displaying original size sensor transmission data
B/W Level1
B/W LEVEL setting original size sensor threshold value
Data2
Displaying original size sensor transmission data
(when DP is installed)
Display
Description
Original Area R
Detected original width size (R)
Original Area G
Detected original width size (G)
Original Area B
Detected original width size (B)
Original Area
Detected original width size
Size SW L
Displays the original size sensor (OSS) ON/OFF
Содержание DP 770
Страница 1: ...Service Manual Document Processor D3 Rev 0 Date 0 201 3NVSM06 ...
Страница 2: ...Service Manual Document Processor D3 Rev 0 Date 0 201 3NVSM06 ...
Страница 5: ...This page is intentionally left blank ...
Страница 11: ...This page is intentionally left blank ...
Страница 17: ...3NV 1 1 4 This page is intentionally left blank ...
Страница 21: ...3NV 1 2 4 This page is intentionally left blank ...
Страница 67: ...3NV 1 3 46 This page is intentionally left blank ...
Страница 85: ...3NV 1 5 10 This page is intentionally left blank ...
Страница 87: ...3NV 1 6 2 This page is intentionally left blank ...
Страница 95: ...3NV 2 1 8 This page is intentionally left blank ...