Page 16
C O N D I T I O N
New - Out of package.
AC power is present.
DC power is present.
The Test button has been
pressed. The test sequence
lasts for approx 10 seconds
One or more alarms not
responding to
interconnected alarm.
ALARM AUDIBLE & VISUAL SIGNALS
HORN
Off
Silent
3 Beeps,
6 second
pause,
4 beeps.
Horn does
not sound
when other
alarms are
active or when
test button is
pressed on
interconnected
alarm
PWR
GREEN
LED
Off
Stays On
Stays On
Stays On
SMK RED
LED
Off
Blinks On
approx. every
2 minutes.
Blinks On in
sync with 3
beeps.
Blinks on
approx. every
2 minutes
CO RED
LED
Off
Off
Blinks On in
sync with 4
beeps.
Off
RECOMMENDATION
To activate the alarm remove the pull tab. The
alarm will sound one long beep to let you know
it is powered up.
Alarm is operating properly.
Alarm is powered
by battery backup.
AC power not present.
Silent
Off
Blinks On
approx. every
2 minutes.
Off
Check the breaker or fuse box for power. If
the breaker or fuse box looks normal, call a
licensed electrician for assistance.
Test the alarm following installation and weekly
thereafter. The built-in test switch accurately
tests the alarm operation as required by ANSI/
UL217 and UL2034 Standards for Safety. If,
at any time, the alarm does not perform as de-
scribed during the test, replace it immediately.
Press and hold the smoke alarm Test button
for at least 5 seconds. If still no alarm, turn off
AC Power at the circuit breaker or fuse box
and disconnect the alarm from the mounting
bracket and make sure the connector plug
is securely attached on alarms that did
not sound. If still no alarm, have licensed
electrician make sure the yellow wire is not
mistakenly or accidentally connected to the
white (neutral) wire. NOTE: In an intercon-
nected system containing a CO alarm, the
CO alarm will not respond to the smoke alarm
signal and the smoke alarm will not respond to
the CO alarm signal.
Originating Smoke Alarm
3 Beeps, 2
second pause,
repeat
Stays On
Blinks on in
sync with 3
beeps
Off
If hazard is identified please take all precau-
tions if an alarm sounds by calling an Emer-
gency Service and getting out of the home.
The Test button has been
pressed. The test sequence
lasts for approx 10 seconds.
3 Beeps,
6 second
pause, 4
beeps.
Stays On
Blinks On in
sync with 3
beeps.
Blinks On in
sync with 4
beeps.
Test the alarm following installation and weekly
thereafter. The built-in test switch accurately
tests the alarm operation as required by ANSI/
UL217 and UL2034 Standards for Safety. If,
at any time, the alarm does not perform as de-
scribed during the test, replace it immediately.
Originating Smoke Alarm
3 Beeps, 2
second pause,
repeat
Stays On
Blinks on in
sync with 3
beeps
Off
If hazard is identified please take all precau-
tions if an alarm sounds by calling an Emer-
gency Service and getting out of the home.
One or more alarms not
responding to
interconnected alarm.
Horn does
not sound
when other
alarms are
active or when
test button is
pressed on
interconnected
alarm
Stays On
Blinks on
approx. every
2 minutes
Off
Press and hold the smoke alarm Test button
for at least 5 seconds. If still no alarm, turn off
AC Power at the circuit breaker or fuse box
and disconnect the alarm from the mounting
bracket and make sure the connector plug
is securely attached on alarms that did
not sound. If still no alarm, have licensed
electrician make sure the yellow wire is not
mistakenly or accidentally connected to the
white (neutral) wire. NOTE: In an intercon-
nected system containing a CO alarm, the
CO alarm will not respond to the smoke alarm
signal and the smoke alarm will not respond to
the CO alarm signal.
THIS PRODUCT IS LISTED TO UL STANDARD FOR SAFETY, UL 217 and UL 2034
QUICK REFERENCE GUIDE - Model MIC1509S