background image

Intended use 

11/20

Fl Remote Set

Intended use  

Please observe the instructions in this operating manual as well as 
the operating conditions and permissible data according to the data 
sheet  to  ensure  that  the  system  functions  properly  and  remains 
operational  for  a  long  time.  In  case  of  non-observance  of  these 
instructions as well as in case of unauthorized interventions in the 
system,  any  liability  on  our  part  is  void,  and  the  warranty  on  the 
system and accessories is also void!  

 

The Fl Remote Set consists of three 433 Mhz radio water 
sensors (modified Sonoff DW2-RF door sensors), a radio remote 
control and a KTNNKG 2 channel radio receiver. 

The  radio  receiver  must  be  located  at  the  installation  site  of 
Fl.  The  wireless  water  sensors  can  be  up  to 50  meters 
away (depending on the environment) (bathroom, kitchen, etc.). 

If  a  radio  water  sensor  detects  conductive  drinking  water, 
Fl  is  immediately  shut  off  via  the  radio  receiver.  Any 
number of wireless water sensors can be taught-in. 

The learnable radio remote control can shut off the water or reset 
the Fl. 

The Fl Remote Set contains additional parts to split the 
Fl  I/O  connector.  This  allows  you  to  connect  additional 
Fl accessories if required. 

An alarm reset can be done via the connected Fl or via 
the second channel of the radio receiver via radio remote control. 

 

Any  other  or  further  use  is  considered  to  be  improper.  usetech 
GmbH shall not be liable for any damage resulting from such use. 
The risk is borne solely by the user. 

 

 

Содержание FlowTimer+ Remote Set

Страница 1: ...FlowTimer Remote Set 433 Mhz 2 channel radio control system for the FlowTimer system Instruction manual...

Страница 2: ...2020 Print date 24 11 2020 Copyright usetech GmbH This documentation including all its parts is protected by copyright Any use or modification outside the narrow limits of the copyright law without t...

Страница 3: ...nauthorized use 7 4 System description FlowTimer Remote Set 8 4 1 Scope of delivery FlowTimer Remote Set 8 5 Installation 9 5 1 Placement of the radio water sensors 9 5 2 Placement of receiver splitte...

Страница 4: ...Table of contents 11 20 FlowTimer Remote Set 2 7 Troubleshooting maintenance 15 7 1 Maintenance 15 8 Packing transport storage 16 9 Disposal and conformity 17...

Страница 5: ...The operating instructions must be read and understood 1 1 Symbol explanation DANGER Warns of an immediate danger Non compliance will result in death or serious injury WARNING Warns of a potentially...

Страница 6: ...efers to information in this operating manual or in other documentation Action steps The defined sequence of action steps facilitates the correct and safe use of the system Result Here you will find t...

Страница 7: ...io remote control Operating voltage 6V 2x CR2016 battery Battery life approx 12 months Transmission frequency 433 MHz Permissible ambient temperature 0 C 40 C Dimensions L 53 x W 37 x H 14 mm 2 3 Envi...

Страница 8: ...eceiver must be located at the installation site of FlowTimer The wireless water sensors can be up to 50 meters away depending on the environment bathroom kitchen etc If a radio water sensor detects c...

Страница 9: ...er It can only be used within an I O connection between FlowTimer and FlowTimer Hub to connect accessories The water sensors are only suitable for electrically conductive drinking water The FlowTimer...

Страница 10: ...ry FlowTimer Remote Set Fig 4 1 Scope of delivery FlowTimer Remote Set 1 Radio Receiver 2 Wireless water sensor 3 pieces 3 Radio remote control battery included 4 battery 27A 12V 3 pieces 5 I O Splitt...

Страница 11: ...e water sensor to protect them from water in case of flooding 5 3 Electrical connection Plug the I O receiver cable 10 of the radio receiver 1 into the FlowTimer I O connector If the connector is alre...

Страница 12: ...e 9 is somewhat short if necessary use the DC extension cable 7 5 4 Commissioning Open the three wireless water sensors 2 by carefully without tools levering the covers bottom side with the four golde...

Страница 13: ...or 1 second The LED goes out after a short time You now have about 10 seconds to teach a water sensor To connect a water sensor 2 to the radio receiver 1 bridge two contact surfaces 13 short distance...

Страница 14: ...ceiver for 1 second The LED goes out after a short time You now have approx 10 seconds to teach a remote control To teach the remote control 3 press the button 15 and then the button 14 The red LED ab...

Страница 15: ...bridge the sensor surfaces 13 of each water sensor one after the other at the final operating location by placing it on a damp cloth The FlowTimer should then shut off after approx 5 seconds Reset the...

Страница 16: ...locked or reset via the remote control 6 1 2 Restarting the system An alarm reset can be done via radio remote control via the connected FlowTimer or its supply voltage A further prerequisite is that...

Страница 17: ...n If the connected FlowTimer shuts down without any reason disconnect the I O of the receiver 10 from the I O connector of FlowTimer Now check your FlowTimer system according to the instructions of th...

Страница 18: ...protected from moisture and dirt in shockproof packaging Avoid exceeding or falling below the permissible bearing temperature Protect electrical connections from damage with protective caps The system...

Страница 19: ...store free of charge Disposal in household waste is expressly prohibited according to the Ordinance on Waste Equipment You can return devices received from us free of charge after use by sending them...

Страница 20: ...Disposal and conformity 11 20 FlowTimer Remote Set 18...

Страница 21: ...Disposal and conformity 11 20 FlowTimer Remote Set 19...

Страница 22: ...Disposal and conformity 11 20 FlowTimer Remote Set 20...

Отзывы: