3
GENERAL REQUIREMENTS
General hand/tools such as combination wrenches, tape measure, level, clamps, etc. are required.
Your particular installation may require a drill or other hardware not provided. Welding by a
qualified welder is the recommended method of securing the linear actuator mounts to the gate
and hinge post. Bolt on brackets is an option, but they must be very securely attached (i.e.
carriage bolts with lock nuts and washers). Lag type bolts are not recommended. Loose or
unstable operator mounts will result in improper operation.
BATTERY REQUIRED FOR OPERATION (NOT INCLUDED).
We recommend a +12 vdc deep cycle Gel or AGM battery rated at a minimum of 33-amp hours.
The actuator harness is equipped with 3/8” ring terminals designed to connect to bolt type battery
posts. The USAutomatic charger is designed for this type of battery. Using a smaller amp hour
battery may cause damage to the charging system.
IMPORTANT CAUTIONS:
1. Do not test or operate this unit without the actuator securely attached to the gate. Serious
damage to the actuator limit switch assembly may occur if attempted.
2. Do not perform any welding while the actuator cable is plugged into the control board or with
the battery connected. Serious damage to the control board and/or battery will occur if
attempted.
3. Always disconnect the battery power from the unit prior to connecting any devices.
GATE QUALIFICATIONS/APPLICATIONS
GATE LENGTH/WEIGHT
This gate operator is rated for vehicular class I or class II swing gates up to 16 feet in length and
up to 650 pounds in weight, as defined by UL-325. If your gate exceeds either one of these
limits, please consult a qualified technician or the factory for alternative solutions.
(Example: Convert one 20' gate into two 10' gates and use a dual gate operator.)
Note:
The total gate opening normally cannot exceed 110 degrees.
Consult a service technician or the factory if greater opening is required.
GATE CYCLES PER DAY
Solar charged systems have a limit on the number of cycles they can provide on a daily basis.
System design must consider stand-by current consumption of all accessories and number of
cycles expected per day. A solar operator will not need additional solar panels in most
installations if solar friendly accessories are used. Contact the factory for help designing a solar
friendly system. This actuator type opener, whether AC or Solar charged, should never be used in
applications, that require 150 or more complete open/close cycles per day. Holding the gate open
can decrease cycles during high cycle time periods. A high traffic gate operator should be used if
more cycles are required.