32
Event→Exception
“Exception Type” includes ”HDD FULL ”,”HDD Error”, ”Network Disconnected”, ”IP address
conflict”
“Normal Linkage” includes “Notify surveillance Center”, “Capture”
“Other Linkage” includes corresponding alarm output channel.
After modifying related parameter, need to click [save] to save settings.
Picture 3.2.6-32 Exception
Storage→Record Schedule
Tick “enable record schedule”, click “Editor" could edit record schedule, appoint record
period and choose type. See picture 3.2.6-33. For edit schedule, see picture 3.2.6-34
Record time includes “all day”, “section”, if choose “section”, user could choose time period
specifically, supports 4 record period settings.
Record Type includes “Timing”, ”Motion Detection”, ”Alarm”, ”Motion Or Alarm”, ”Motion
and Alarm”, ”Other”.
Pre-record is the advanced record time before starting of record, 0-3sec (optional) and not
limit.
Post-record is the delayed time of record, 5sec-10min (optional)
After modifying related parameter, need to click “confirm” to save settings
Note: Overwrite is measured according to 2Mbps, the bigger scream you choose, the shorter, he
pre-record time is.