![USA Measurements US-6011 Series Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/usa-measurements/us-6011-series/us-6011-series_user-manual_1063857023.webp)
Page 23
RS232 SERIAL OUTPUT FORMAT
When connecting the indicator to the RS-232 Serial device, follow the pin out of Table 5
below.
Table 5. DB9 Pin Description
DB9 Pin
Definition
Definition
2
TXT
Transmit Data
3
RXD
Receive Data
5
GND
Ground Interface
The serial output format depends on the settings for parameter C18. The serial output
consists of a string of ASCII characters. Here is a list of the serial parameters
• 8 data bits
• 1 stop bits
• No parity
• No handshaking
Note: With the RS232 Output option we have data logging software available as seen in
[Insert figure no.].
Below are the formats of the serial output
• C18=0 - Turn off serial interface data output
• C18=1 - Continuous sending mode, connect 2nd big display
• C18=2 - Print mode, connect printer
• C18=3 - Command request mode, connect computer.
• C18=4 - PC continuous sending mode, connect computer
• C18=5 - PC/big display, continuous sending mode
• C18=6 - Print to adhesive label printer
• C18=7 - Print to Zebra adhesive label printer
•