Страница 1: ...USA Measurements US 1011 Indicator User Manual R1 1 ____________________________________________________________________...
Страница 2: ...BOOKMARK NOT DEFINED 2 2 RS232 PORT ERROR BOOKMARK NOT DEFINED 2 3 LOA D CELL PORT ERROR BOOKMARK NOT DEFINED 3 0 OPERATION 4 3 1 INDICATING LAMPS 4 3 2 OPTIONAL BUTTIONS ERROR BOOKMARK NOT DEFINED 4...
Страница 3: ...MULATION FUNCTION 10 5 3 COUNTING FUNCTION 10 APPENDIX 1 INDICATOR PROMPT MESSAGE ERROR BOOKMARK NOT DEFINED APPENDIX 2 SERIAL PORT OUTPUT FORMAT 13 APPENDIX 3 PRINTING OUTPUT FORMAT ERROR BOOKMARK NO...
Страница 4: ...at full scale 1 10 mV Inner resolution 1 million Display division 1000 30000 A D sampling rate 120times sec Power supply mode Battery 7 4V 4AH lithium battery Adaptor input voltage 100 240 VAC output...
Страница 5: ...FACE 2 1 Power supply 1Pin inner core DC 2Pin outer coreA DC 2Pin TXD 3Pin RXD 5Pin GND 2 1Pin E 2Pin SN 5Pin SHLD 6Pin E 7Pin SN 8Pin S 9Pin S 3 0 Operation 3 1 indicating lamps sign Analysis Remark...
Страница 6: ...in use accumulation The lamp is on when the accumulation function is in use Weight unit The weight unit in use Battery power The power is too low and charge the battery in time Button indicator This s...
Страница 7: ...oss weight Move cursor to the right TARE Skin removal gross weight net weight Decrease number ZERO Zeroing Increases number PRINT Short press start up when the indicator is off Long press shut down wh...
Страница 8: ...te when F1 2 F1 3 or F1 4 is being set division value should not be beyond 10000 F1 4 Zero calibration remove weights off the scale and make sure there is nothing on the scale Press PRINT and the scre...
Страница 9: ...able parameters 0 sorting default 1 accumulation 2 counting F1 11 Restoring factory default Selectable parameters 0 no restore 1 restore parameters from F1 F4 while scale parameters will not be affect...
Страница 10: ...is ineffective F4 Serial port communication F4 1 Communication method Selectable parameters 0 no output default 1 continuous output only when the indicator is at stable state 2 printing output format...
Страница 11: ...Suppose the current weight is Wt the empty scale range is Ewt the sorting lower limit is Lwt the sorting upper limit is Swt Make sure Swt Lwt Ewt and then Wt Ewt off Wt Lwt on Lwt Wt Swt on Wt Swt on...
Страница 12: ...in general situation Once an error occurs please make clear the error first and observe whether the instrument still has error after power on Do not hurry to repair the scale body or instrument Repai...
Страница 13: ...ements 13 It has enters menu setting Press Print to continue setting 14 End of zero point and loading point calibration 15 Loading default value Appendix 2 Serial port output format Serial port contin...
Страница 14: ...13 U S N T sp sp 0 2 0 0 k g 0d 0a Appendix 3 Printing output format LIST Date 2018 04 14 Time 15 08 46 Gross 2 061kg Tare 0 000kg Net 2 061kg LIST Date 2018 04 14 Time 15 10 18 Count 206PCS...