background image

Installation Instructions 

Residential Reverse Osmosis Drinking Water System 

Page 3 

Parts Check List 

 

RO Module 

 

Tubing Bundle 

 

Filter Wrench 

 

Drain Saddle 

 

Tank Valve 

 

Angle Stop Feed Valve 

 

Tank and Side Mount Tank Stand 

 

Faucet and Mounting Kit 

 

Faucet Connector 

 

Pre and Post Filters 

 

Membrane 

 

Installation Instructions 

COMPONENTS 

The  following  components  make  up  your  Reverse 
Osmosis Drinking Water System: 

PRE-FILTER 

(sediment  filter)  removes  larger  particles 

such as sand, silt, rust and scale,

 

(activated carbon filters) 

remove  chlorine  in  the  feed  water  to  protect  the  reverse 
osmosis membrane. 

REVERSE 

OSMOSIS 

MEMBRANE 

reduces 

dissolved 

minerals, metals and salts. During the process, 

harmful compounds are separated by the membrane and 
the reject water goes to waste (drain). 

An activated carbon 

POST-FILTER 

is provided for a final 

“polish”  and  to  remove  foul  tastes,  odors  and  to  provide 
great tasting drinking water. 

FILTER HOUSINGS 

and 

R/O MODULE 

hold pre-filters 

and  membranes.  A 

BRACKET 

is  provided  so  they  may 

be mounted, typically below sink. 

STORAGE TANK 

holds filtered water, ready for use. 

AUTOMATIC  SHUT-OFF  VALVE  (ASO) 

senses 

when the storage tank is full and closes the water supply 
to conserve water.  (not used in permeate pump system) 

PERMEATE  PUMP

  is  used  to  pressurize  the  tank  and 

distribution  system.    This  pump  is  operated  by  the  drain 
water.  The permeate pump will dramatically increase the 
faucet  pressure.  A  permeate  pump  system  will  not  have 
an ASO valve. 

The  dedicated 

FAUCET 

is  used  to  dispense  RO 

produced water when needed. 

FEED WATER ANGLE STOP VALVE 

is connected to 

the cold water line to supply water to the R/O system. 

 
WASTE WATER SADDLE VALVE 

is connected to the 

drain to remove reject water from the R/O system. 

TUBING 

supplies feed and reject water. 

FITTINGS 

are used for necessary hose connections. 

Tools 

The following tools may be necessary, depending on 
each particular installation: 

3/8” Drill and ¼” drill bit and Faucet Drill bit (Standard 
Faucet use a 7/16” drill bit) 
Phillips head and flat blade screwdrivers 
Adjustable wrench 
Crescent wrench 
Teflon tape 
Plastic tube cutter 

System location 

Your  R/O  system  may  be  installed  under  a  sink,  in  a 
basement or other location, depending on available space. 
Do  not  install  unit  where  temperatures  fall  below  freezing; 
otherwise,  damage  will  result.  Connection  to  an  icemaker 
should also be considered for optimum performance. 

Guidelines for component placement are as 
follows: 

FAUCET 

should  be  placed  near  the  sink  where  drinking/ 

cooking  water  is  normally  required.  A  2”  flat  surface  is 
required to mount the faucet if an existing hole for a second 
faucet  is  not  available.  The  thickness  of  the  mounting 
surface should not exceed 1-1/4”. 

Содержание american revolution

Страница 1: ...Aquapurion 5 Stage Standard Plus And Permeate Pump RO Systems Installation And Maintenance Manual...

Страница 2: ...MEMBRANE POST CARBON PRE SEDIMENT PRE CARBON FAUCET AND MOUNTING KIT FILTER WRENCH DRAIN SADDLE FEED WATER ANGLE STOP TANK VALVE FAUCET CONNECTOR TUBING...

Страница 3: ...MP is used to pressurize the tank and distribution system This pump is operated by the drain water The permeate pump will dramatically increase the faucet pressure A permeate pump system will not have...

Страница 4: ...the installation Make sure you have a pan and paper towels to catch and dry the area UNIT PREPARATION Open shipping carton remove components and check that all parts are present Check empty storage ta...

Страница 5: ...e turn off the cold water supply valve for the sink faucet Open the sink faucet cold water and relieve the pressure Remove the sink faucet whip hose or tubing from the shutoff valve There will be resi...

Страница 6: ...the bottom A side or top position is recommended Install rubber gasket on this half of the drain saddle Be sure the gasket hole is lined up with the port hole 2 Drill 1 4 hole at mark through one side...

Страница 7: ...lace When installing the membrane be sure that it is fully seated in the membrane housing H RO unit installation The RO unit is normally mounted to the sink cabinet sidewall depending on where supply...

Страница 8: ...maker valve and ice maker unit Turn back on only after RO tank is full System start up Prior to start up 1 Check all connections to be sure they are secure 2 Turn on feed water valve and check for lea...

Страница 9: ...8 After fifteen minutes do the following in order 9 Close feed water valve 10 Close holding tank valve while faucet is open to release pressure 11 Remove housings and empty them 12 Remove any protecti...

Страница 10: ...at standard conditions of 77 F 25 C and 60 psi 4 bar discharging to atmosphere In general the higher the pressure differential and temperature the greater the quality and quantity of water produced Th...

Страница 11: ...the site and or before use Disconnecting Push in Collet and remove tube To disconnect ensure the system is depressurized before removing the tube Push in collet squarely against face of fitting With...

Страница 12: ...Installation Instructions Residential Reverse Osmosis Drinking Water System Page 12 Green Tube...

Страница 13: ...Installation Instructions Residential Reverse Osmosis Drinking Water System Page 13 Green Tube...

Страница 14: ...bing on the refrigerator ice maker or use the 7 16 x 3 8 water inlet solenoid adaptor If the solenoid adaptor is used remove the 1 4 existing line nut and sleeve then screw the adaptor to the water in...

Страница 15: ...Installation Instructions Residential Reverse Osmosis Drinking Water System Page 15...

Страница 16: ...o not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the unit NOTE Activated carbon cartridges and carbon block cartridges may cont...

Страница 17: ...everse Osmosis Membrane GENERAL PROVISIONS This warranty does not apply to any commercial or industrial installations or to any part of the reverse osmosis system which has been subjected to misuse ne...

Отзывы: