Ice Maker Kit Installation Instructions 

 
1.  Cut the 3/8" line that goes to the faucet and insert the 3/8" tee fitting.  
2.  Attach the 3/8" tubing that came with the kit to the open port on the tee.  
3.  Cut this tube about 2" after the 3/8" tee. Insert the shut off valve.  
4.  Attach the remaining 3/8" tubing to the other end of the valve.  
5.  Now run the 3/8" tubing to the refrigerator/ice maker close to the water inlet solenoid.  
6.  Once the tubing is routed to the refrigerator/ice maker, use the 3/8" to 1/4" adaptor to the existing 1/4" tubing on 

the refrigerator/ice maker or use the 7/16" x 3/8" water inlet solenoid adaptor. If the solenoid adaptor is used, 
remove the 1/4" existing line nut and sleeve, then screw the adaptor to the water inlet solenoid. No sealant or 
teflon tape is required for solenoid adaptor. It is a compression fitting. Tighten the fitting and insert the 3/8" tub-
ing. Leave the ice maker off until the RO system is flushed and full. 

7.  When the RO system is full, turn on the ice maker shutoff valve and the ice maker shutoff lever or switch.   
8.  Disregard the first two batches of ice.  This will flush the internal tubing in the ice maker or refrigerator. 
9.  If there is a filter in the refrigerator or ice maker be sure to bypass it or make sure it is change annually with the 

RO system filter.   

 
Flow Schematic is on the next page. 

Содержание american revolution

Страница 1: ...Aquapurion 5 Stage Standard Plus And Permeate Pump RO Systems Installation And Maintenance Manual...

Страница 2: ...MEMBRANE POST CARBON PRE SEDIMENT PRE CARBON FAUCET AND MOUNTING KIT FILTER WRENCH DRAIN SADDLE FEED WATER ANGLE STOP TANK VALVE FAUCET CONNECTOR TUBING...

Страница 3: ...MP is used to pressurize the tank and distribution system This pump is operated by the drain water The permeate pump will dramatically increase the faucet pressure A permeate pump system will not have...

Страница 4: ...the installation Make sure you have a pan and paper towels to catch and dry the area UNIT PREPARATION Open shipping carton remove components and check that all parts are present Check empty storage ta...

Страница 5: ...e turn off the cold water supply valve for the sink faucet Open the sink faucet cold water and relieve the pressure Remove the sink faucet whip hose or tubing from the shutoff valve There will be resi...

Страница 6: ...the bottom A side or top position is recommended Install rubber gasket on this half of the drain saddle Be sure the gasket hole is lined up with the port hole 2 Drill 1 4 hole at mark through one side...

Страница 7: ...lace When installing the membrane be sure that it is fully seated in the membrane housing H RO unit installation The RO unit is normally mounted to the sink cabinet sidewall depending on where supply...

Страница 8: ...maker valve and ice maker unit Turn back on only after RO tank is full System start up Prior to start up 1 Check all connections to be sure they are secure 2 Turn on feed water valve and check for lea...

Страница 9: ...8 After fifteen minutes do the following in order 9 Close feed water valve 10 Close holding tank valve while faucet is open to release pressure 11 Remove housings and empty them 12 Remove any protecti...

Страница 10: ...at standard conditions of 77 F 25 C and 60 psi 4 bar discharging to atmosphere In general the higher the pressure differential and temperature the greater the quality and quantity of water produced Th...

Страница 11: ...the site and or before use Disconnecting Push in Collet and remove tube To disconnect ensure the system is depressurized before removing the tube Push in collet squarely against face of fitting With...

Страница 12: ...Installation Instructions Residential Reverse Osmosis Drinking Water System Page 12 Green Tube...

Страница 13: ...Installation Instructions Residential Reverse Osmosis Drinking Water System Page 13 Green Tube...

Страница 14: ...bing on the refrigerator ice maker or use the 7 16 x 3 8 water inlet solenoid adaptor If the solenoid adaptor is used remove the 1 4 existing line nut and sleeve then screw the adaptor to the water in...

Страница 15: ...Installation Instructions Residential Reverse Osmosis Drinking Water System Page 15...

Страница 16: ...o not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the unit NOTE Activated carbon cartridges and carbon block cartridges may cont...

Страница 17: ...everse Osmosis Membrane GENERAL PROVISIONS This warranty does not apply to any commercial or industrial installations or to any part of the reverse osmosis system which has been subjected to misuse ne...

Отзывы: