background image

Multímetro Digital

Digital Multimeter

UD12

ATENCIÓN:

 Lea, entienda y siga las instrucciones de seguridad contenidas en este docuemento, antes 

de operar esta herramienta.

WARNING: Read, understand and follow the safety rules in this document, before operating this tool.

Manual de Usuario y Garantía.

User’s Manual and Warranty.

Содержание UD12

Страница 1: ...ienda y siga las instrucciones de seguridad contenidas en este docuemento antes de operar esta herramienta WARNING Read understand and follow the safety rules in this document before operating this to...

Страница 2: ...RADIACI N ELECTROMAGN TICA QUE PODR A INDUCIR VOLTAJES EN LAS PRUEBAS PRINCIPALES DEL MULT METRO EN ESOS CASOS LA PRECISI N DEL MULT METRO NO ES GARANTIZADA POR RAZONES F SICAS CONTENIDO 1 INTRODUCCI...

Страница 3: ...DESCONECTE LA POTENCIA INMEDIATAMENTE Y CHEQUE DE NUEVO TODAS LAS CONEXIONES Lea la siguiente informaci n cuidadosamente antes de operar o hacer servicio del medidor Nunca trate de medir un voltaje q...

Страница 4: ...p de continuidad Si esto no sucede revise si las puntas de prueba est n bien insertadas o posicione el interruptor nuevamente en la funci n 4 Aplique las puntas de prueba al circuito bajo prueba y lea...

Страница 5: ...ESPECIFICACIONES GENERALES M ximo voltaje entre cualquier terminal y tierra 600 V Pantalla Digital 3 d gitos 2000 cuentas con indicaci n autom tica de polaridad Tiempo de Lectura De 2 a 3 lecturas po...

Страница 6: ...TTERS AND CELLULAR PHONES GENERATE ELECTROMAGNETIC RADIATION THAT MAY INDUCE VOLTAGES IN THE TEST LEADS OF THE MULTIMETER CANNOT BE GUARANTEED DUE TO PHYSICAL REASONS CONTENT 1 INTRODUCTION 7 2 SAFETY...

Страница 7: ...S TO THIS METER AND THEN TO THE CIRCUIT UNDER TEST REAPPLY POWER IF AN ERRONEOS READING IS OBSERVED DISCONNECT POWER IMEDIATELY AND RECHECK ALL SETTINGS AND CONNECTIONS Read the following safety infor...

Страница 8: ...e Meter should display a on the LCD 3 Short the leads and see that the display reads 0 2 and the continuity beeper sounds If not check the test eads insertion or position of the function switch again...

Страница 9: ...PECIFICACIONES GENERALES Maximum Voltage between any terminal and earth 600 V Digital Display 3 digits 2000 counts with automatic polarity indication Reading Time 2 3 readings per second Input Impedan...

Страница 10: ...10 NOTAS NOTES...

Страница 11: ...11 NOTAS NOTES...

Страница 12: ...casos a Cuando la herramienta se haya utilizado en condiciones distintas a las normales b Cuando el producto hubiera sido alterado de su composici n original o reparado por personas no autorizadas por...

Отзывы: