Motor speed
4-1
Slow
The factory setting is « 4-3 »
4-2
Middle
4-3
Fast
4-4
Very fast
5
The deceleration
setting for gate
moving
5-1
75% of full distance
The factory setting is « 5-1 »
5-2
80%
5-3
85%
5-4
90%
5-5
95%
6
Deceleration
speed
(% full speed)
6-1
80%
The factory setting is « 6-3 »
6-2
60%
6-3
40%
6-4
25%
7
Force of motor
7-1
2A
The function can adjust the running
force of motor to be compatible with
the gate weight.
The factory setting is « 7-5 »
7-2
3A
7-3
4A
7-4
5A
7-5
6A
7-6
7A
8
Open partially
(pedestrian
opening)
8-1
10%
This function can adjust the width of
opening partially.
The factory setting is « 8-2 »
8-2
20%
8-3
30%
8-4
40%
8-5
50%
8-6
60%
9
Pre-Flashing
9-0
The flashing light
blinks when the
gate starts to move
The factory setting is « 9-0 »
9-1
The flashing light
blinks 3 seconds
before the gate
starts to move