30
EN
LED flashing light with integrated antenna
Coaxial
black wire
24V DC
Coaxial cable
Braided shield
Copper core
If you want to improve the operating range
of your remote, you can connect the blinker
antenna with a RG58 coaxial cable (not supplied).
In this case you must disconnect the original
antenna and then connect the coaxial copper
core to the terminal ANT and the coaxial braided
shield to the terminal GND on both antenna and
electronic card.
Placed at the top left of PCB
press
Fixing screw