DS1067-063D
107
LBT20064
To delete the address of the 1067/026 keypad, follow the instructions below:
1. Open the tamper contact (release the keypad from the relative bracket - see
Figure 49 - Removal of the 1067/026
2. Press the
T4
key for at least 5 seconds. This will appear on the display:
3. Press
T1
to confirm or
T4
to cancel.
In reference to the radio expansion reset, it is also necessary to reacquire all the radio devices associated with it.
IMPORTANT!
Following the Reset command of the radio expansion, it is necessary to carry out the local reset of
all the radio sirens of the system
and then reacquire them.
7.10 REPLACING THE BATTERY
When a battery can no longer maintain its charge, it must be replaced with a similar one in order not to compromise the
correct functioning of the system.
To replace the battery, follow the instructions below:
1. Activate the Maintenance status (see paragraph 7.1
) and open the device containing the battery.
2. Disconnect the old battery and remove it.
3. Insert the new battery and connect it with the special connectors, matching the polarity.
4. Close the device.
5. Carry out a Test battery check (see the
Programming Manual
).
WARNING.
The disposal of lead batteries is regulated by precise law and they must be delivered to
special collection centres.
7.11 TURNING OFF THE ENTIRE SYSTEM
Whenever the entire system must be turned off, follow the instructions below:
1. Activate Maintenance status (see paragraph 7.1
) and open the control panel.
2. Disconnect the mains power supply.
3. Disconnect the battery.
4. If supplemental power supply units are present, disconnect them in the same sequence (points 2 and 3).
Before restoring power, wait at least 1 minute.
IMPORTANT!
It is fundamental to put the control panel in Maintenance status before turning it off.
Failure to follow these instructions may cause a loss of data and compromise the correct functioning of the