MAINTENANCE PROCEDURE
II. Protective Function & Alarm Display by LED
▶
3 LEDS BLINK ONCE SIMULTANEOUSLY: OUTPUT CONNECTION ERROR.
-> CHECK THE BATTERY AND CHARGER CONNECTION AND CORRECT
▶
3 LEDS BLINK THREE TIMES SIMULTANEOUSLY: CHARGER IS OVERHEATED.
-> NO ACTION REQUIRED. WHEN THE CHARGER COOLS, CHARGING WILL RE-
START AUTOMATICALLY.
▶
3 LEDS BLINKS FOUR TIMES SIMULTANEOUSLY: INPUT OR OUTPUT OVER
CURRENT.
-> NO ACTION REQUIRED, CHARGER WILL CORRECT AND RE-START
AUTOMATICALLY.
▶
100% LED BLINKS WHILE 50% AND 75% LED'S ARE "OFF"
->THE 18-HOUR TIMER HAS ELAPSED AND STOPPED BATTERY CHARGING.
BATTERIES ARE UNABLE TO COMPLETE CONSTANT CURRENT AND
CONSTANT VOLTAGE CHARGE CYCLE.
1) Batteries are very extremely discharged. Unplug and then plug-in charger to re-start
charge cycle to complete charging.
2) Batteries are weak, old, or have one or more bad cells. Batteries will still charge but
capacity will be reduced. Replace batteries.
Take care to properly secure the wires. If not you will end up with burnt
terminals due to loose wires