CONTROL VALVE - CAGE
Is shown on the diagram below.
The relief valve shown here is set at 140
Bar and should be adjusted in
accordance with the setting up procedure.
Shown elsewhere, see section :
The relief valve can be seen on the
picture insert in the bottom right hand
corner. Remove cap and screw adjusting
screw in to increase pressure and out to
decrease pressure. Put cap back after
adjusting
The spools are all the same. They are all closed centre in the neutral position. It is critical
that the valve block does not leak internally when in the neutral position. Remember you
have two valve blocks. Each is connected together at the lift cylinders. If the Ground valve is
not leak free, with the spool in the neutral position, when operating the Cage valve, the oil will
not go into the cylinder but leak out (internally) through the Ground valve. This can also
happen if the spool is not properly centralised by the spring at the end of the spool.
The same thing is true if you operate the Ground controls and the Cage valve is leaking
internally.
The normal symptom for this problem is when the operator reports that
“everything works
fine from the ground controls but when operating from the cage, boom x does not move.
Motor runs but nothing happens.”
In this case the valve which makes the boom work
correctly is in fact the valve which is at fault!
140 BAR
CAGE VALVE
Pressure relief Valve
* Section from drawing 01-0341
MAINTENANCE PROCEDURE
Page 21
Содержание POWERED ACCESS TL34
Страница 2: ......
Страница 4: ......
Страница 5: ......
Страница 20: ...FIG 5 14 SETTING UP MOTOR RUN HYDRAULIC VALVE LEVERS LEVEL BUBBLE Hydraulic Outriggers ...
Страница 33: ......
Страница 49: ...MAINTENANCE PROCEDURE Page 15 ...
Страница 50: ...MAINTENANCE PROCEDURE Page 16 ...
Страница 78: ...Page 44 ...