EMERGENCY CONTROLS
Emergency Procedures (from the Ground) – Without Power
1.
Turn the 2 ball valves fitted under the cabinet 90 degrees (
Fig 16
)– photo below
shows normal operating position.
boom cylinders. (
FIG. 17 )
Start with the bottom boom cylinder first to ease access to the top boom cylinder.
3.
The 2 ball valves MUST be returned to the normal operating position (as
shown) before operating the machine. If they are not, you will not be able to
elevate the booms.
Emergency Battery Isolating Plug
This plug when disconnected, will isolate the batteries from the power pack and operating
circuits. (
FIG.18
)
NOTE: Before operation of the machine, it is important that both the Operator and some
other responsible person on site, is aware of the position and function of the following:
Emergency Stop Buttons:
Fig.12
Emergency Lowering:
FIG. 16 & 17
Emergency Slew:
FIG. 14
Battery Isolating:
FIG. 18
BALL VALVE
FIG. 16
RED EMERGENCY LOWER KNOB
FIG. 17
FIG. 18
21
EMERGENCY
BATTERY
DISCONNECT PLUG
2. Now pull on the red emergency lower knob on the solenoid fitted to the top and botton